COMBINATION RATINGS Continued
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | ARI STANDARD RATINGS* | 
 | 
 | 
 | 
 | |||
| 
 | 
 | 
 | 
 | 
 | Cooling | 
 | 
 | 
 | 
 | 
 | Heating | 
 | 
 | |
| 
 | 
 | 
 | 
 | Seasonal Efficiency SEER | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 
 | 
 | 
 | 
 | Factory- | 
 | 
 | 
 | 
 | ||||||
| 
 | 
 | 
 | 
 | 
 | 
 | Accessory‡ | 
 | 
 | 
 | 
 | 
 | 
 | ||
| UNIT | 
 | 
 | 
 | Supplied | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| SIZE- | INDOOR | 
 | 
 | Enhance- | Standard | Puron | PuronTXV | 
 | 
 | 
 | 
 | 
 | 
 | |
| SERIES | UNIT | CFM†† | TC | ment | Rating | 
 | TXV | & TDR** | EER | TC | COP | TC | COP | HSPF | 
| 
 | CJ5A/CK5A/CK5BA060 | 1400 | 45,000 | NONE | — | 
 | — | 12.50 | 10.75 | 48,000 | 3.50 | 28,600 | 2.38 | 8.20 | 
| CJ5A/CK5A/CK5BN060 | 1400 | 45,500 | NONE | — | 
 | — | 13.00 | 10.90 | 48,500 | 3.52 | 28,600 | 2.38 | 8.25 | |
| CJ5A/CK5A/CK5BX060 | 1400 | 45,500 | NONE | — | 
 | — | 13.00 | 10.90 | 48,500 | 3.52 | 28,600 | 2.38 | 8.25 | |
| 
 | 
 | |||||||||||||
| 
 | CK3BA060 | 1400 | 45,000 | NONE | — | 
 | — | 12.50 | 10.75 | 48,000 | 3.50 | 28,600 | 2.38 | 8.20 | 
| 
 | FV4ANB006† | 1750 | 58,000 | TDR&TXV | 13.00 | 
 | — | — | 10.75 | 60,000 | 3.56 | 37,000 | 2.54 | 8.00 | 
| 
 | FB4ANB070 | 1750 | 57,000 | TDR | — | 
 | 12.00 | — | 10.20 | 60,000 | 3.44 | 37,800 | 2.46 | 7.80 | 
| FC4BNB070 | 1750 | 57,000 | TDR | — | 
 | 12.00 | — | 10.20 | 60,000 | 3.44 | 37,800 | 2.46 | 7.80 | |
| FK4CNB006 | 1750 | 58,000 | TDR | — | 
 | 12.80 | — | 10.75 | 59,500 | 3.56 | 37,000 | 2.54 | 8.00 | |
| 
 | FX4ANB060 | 1750 | 57,000 | TDR&TXV | 12.00 | 
 | — | — | 10.20 | 60,000 | 3.44 | 37,800 | 2.46 | 7.80 | 
| 
 | CC5A/CD5AW060 | 1750 | 56,000 | NONE | — | 
 | — | 12.50 | 10.45 | 58,500 | 3.26 | 36,800 | 2.42 | 7.50 | 
| 
 | CJ5A/CK5A/CK5BX060 | 1750 | 56,500 | NONE | — | 
 | — | 12.50 | 10.55 | 59,000 | 3.44 | 37,000 | 2.50 | 7.70 | 
*Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on: Cooling Standard: 80°F (27°C) db 67°F (19°C) wb indoor entering air temperature and 95°F (35°C) db air entering outdoor unit. 
†Outdoor section/indoor section combination tested in accordance with DOE test procedure for heat pumps.
‡ Based on computer simulation. TXV must be Puron compatible and hard shutoff type.
** In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance.
Use either the accessory 
†† Indoor Airflow
COP — Coefficient of Performance EER — Energy Efficiency Ratio
HSPF — Heating Seasonal Performance Factor SEER — Seasonal Energy Efficiency Ratio
TC — Total Capacity (Btuh) TDR — 
TXV — Thermostatic Expansion Valve