Bryant 650A warranty COMBINATION RATINGS Continued

Models: 650A

1 20
Download 20 pages 45.05 Kb
Page 9
Image 9

COMBINATION RATINGS Continued

 

 

 

 

 

 

 

ARI STANDARD RATINGS*

 

 

 

 

 

 

 

 

 

Cooling

 

 

 

 

 

Heating

 

 

 

 

 

 

Seasonal Efficiency SEER

 

 

 

 

 

 

 

 

 

 

Factory-

 

 

Field-Supplied

 

High-Temp

Low-Temp

 

 

 

 

 

 

 

Accessory‡

 

 

 

 

 

 

UNIT

 

 

 

Supplied

 

 

 

 

 

 

 

 

SIZE-

INDOOR

 

 

Enhance-

Standard

Puron

PuronTXV

 

 

 

 

 

 

SERIES

UNIT

CFM††

TC

ment

Rating

 

TXV

& TDR**

EER

TC

COP

TC

COP

HSPF

 

CJ5A/CK5A/CK5BA060

1400

45,000

NONE

 

12.50

10.75

48,000

3.50

28,600

2.38

8.20

048-A,C

CJ5A/CK5A/CK5BN060

1400

45,500

NONE

 

13.00

10.90

48,500

3.52

28,600

2.38

8.25

CJ5A/CK5A/CK5BX060

1400

45,500

NONE

 

13.00

10.90

48,500

3.52

28,600

2.38

8.25

 

 

 

CK3BA060

1400

45,000

NONE

 

12.50

10.75

48,000

3.50

28,600

2.38

8.20

 

FV4ANB006†

1750

58,000

TDR&TXV

13.00

 

10.75

60,000

3.56

37,000

2.54

8.00

 

FB4ANB070

1750

57,000

TDR

 

12.00

10.20

60,000

3.44

37,800

2.46

7.80

060-B,C

FC4BNB070

1750

57,000

TDR

 

12.00

10.20

60,000

3.44

37,800

2.46

7.80

FK4CNB006

1750

58,000

TDR

 

12.80

10.75

59,500

3.56

37,000

2.54

8.00

 

FX4ANB060

1750

57,000

TDR&TXV

12.00

 

10.20

60,000

3.44

37,800

2.46

7.80

 

CC5A/CD5AW060

1750

56,000

NONE

 

12.50

10.45

58,500

3.26

36,800

2.42

7.50

 

CJ5A/CK5A/CK5BX060

1750

56,500

NONE

 

12.50

10.55

59,000

3.44

37,000

2.50

7.70

*Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on: Cooling Standard: 80°F (27°C) db 67°F (19°C) wb indoor entering air temperature and 95°F (35°C) db air entering outdoor unit. High-Temp Heating Standard: 70°F (21°C) db indoor entering air temperature and 47°F (8°C) db 43°F (6°C) wb air entering outdoor unit.

Low-Temp Heating Standard: 70°F (21°C) db indoor entering air temperature and 17°F (–9°C) db 15°F (–10°C) wb air entering outdoor unit.

Outdoor section/indoor section combination tested in accordance with DOE test procedure for heat pumps.

‡ Based on computer simulation. TXV must be Puron compatible and hard shutoff type.

** In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance.

Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. All Bryant furnaces are equipped with TDR except for the 394HAD.

†† Indoor Airflow

COP — Coefficient of Performance EER — Energy Efficiency Ratio

HSPF — Heating Seasonal Performance Factor SEER — Seasonal Energy Efficiency Ratio

TC — Total Capacity (Btuh) TDR Time-Delay Relay

TXV — Thermostatic Expansion Valve

—9—

Page 9
Image 9
Bryant 650A warranty COMBINATION RATINGS Continued