Bryant 663C instruction manual Outdoor Thermostat, or 2 Outdoor Thermostats

Models: 663C

1 12
Download 12 pages 8.06 Kb
Page 6
Image 6
1 Outdoor Thermostat, or 2 Outdoor Thermostats

BRYANT

FA, FB, FC,

PROGRAMMABLE

THERMOSTAT

FD, FF, FH

MODEL HP

FAN COIL

HEAT PUMP

BRYANT

 

 

ONE

PROGRAMMABLE

 

 

THERMOSTAT

FA, FB, FC, FD, FF, FH

HEAT

OUTDOOR

MODEL HP

FAN COIL

PUMP

THERMOSTAT

24 VAC HOT

INDOOR FAN

HEAT STAGE 2

COOL/HEAT STAGE 1

RVS COOLING

NOT USED

24 VAC COM

NOT USED

TROUBLE

OPTIONAL OUTDOOR SENSOR CONNECTION

R

R

 

G

G

W/W1

W2 *

 

Y/Y2

E *

W3 *

 

O/W2

 

Y1/W2

 

C

C

 

B

 

L

* IF AVAILABLE

 

S1

 

S2

 

Manual backgroundManual background R

Manual backgroundManual backgroundW2

Manual backgroundManual background Y

Manual backgroundManual background O

Manual backgroundManual background C

24 VAC HOT

W3

 

 

R

 

 

 

R

R

 

INDOOR FAN

G

 

 

 

G

 

 

HEAT STAGE 2

W/W1

 

 

COOL/HEAT

W2

W2

ODT

Y/Y2

 

 

 

STAGE 1

 

 

 

 

 

 

E

 

 

RVS COOLING

O/W2

 

 

NOT USED

Y1/W2

Y

 

 

 

 

 

O

 

24 VAC COM

C

 

 

 

C

C

 

NOT USED

B

 

 

TROUBLE

L

 

 

OPTIONAL

S1

 

 

OUTDOOR

 

 

 

SENSOR

S2

 

 

CONNECTION

 

 

A97370

NOTE: Remove wires from crimp nut in indoor fan coil when installing outdoor thermostat.

IMPORTANT: When using outdoor thermostat, W2 must be energized when requesting supplemental heat.

A97399

BRYANT

FA, FB, FC,

 

TWO

PROGRAMMABLE

 

THERMOSTAT

FD, FF, FH

HEAT

OUTDOOR

MODEL HP

FAN COIL

PUMP

THERMOSTATS

24 VAC HOT

INDOOR FAN

 

W3

ODT

R

 

 

 

EHR

R

R

G

 

 

 

G

 

BRYANT

 

 

PROGRAMMABLE

FK4C

 

THERMOSTAT

HEAT

MODEL HP

FAN COIL

PUMP

HEAT STAGE 2

COOL/HEAT STAGE 1

RVS COOLING

NOT USED

24 VAC COM

NOT USED

TROUBLE

OPTIONAL OUTDOOR SENSOR CONNECTION

W/W1

 

 

 

W2

W2

Y/Y2

 

 

 

O/W2

 

Y

 

 

EHR

 

O

Y1/W2

 

 

 

 

E

ODT

 

 

C

EHR

 

 

C

B

C

 

 

L

 

 

S1

 

 

S2

 

 

24 VAC HOT

INDOOR FAN

HEAT STAGE 2

COOL/HEAT STAGE 1

RVS COOLING

NOT USED

24 VAC COM

NOT USED

TROUBLE

R

DH

J1 JUMPER

 

 

G

R

R

 

 

 

G

 

W/W1

 

 

 

W1

W2

Y/Y2

W2

J2 JUMPER

 

 

O/W2

Y/Y2

Y

Y1/W2

O

O

C

C

C

B

Y1

 

L

 

 

NOTE: Remove wires from crimp nut in indoor fan coil when installing outdoor thermostats.

IMPORTANT: When using outdoor thermostats, W2 must be energized when requesting supplemental heat.

OPTIONAL OUTDOOR SENSOR CONNECTION

S1

S2

A97400

A97372

Fig. 9ÐTypical 24-v Circuit Connections using Bryant Model HP Thermostat with Fan Coils and No Outdoor Thermostat,

1 Outdoor Thermostat, or 2 Outdoor Thermostats

Ð6Ð

Page 6
Image 6
Bryant 663C instruction manual Outdoor Thermostat, or 2 Outdoor Thermostats