SPECIFICATIONS Continued

UNITS WITH FACTORY-INSTALLED ELECTRIC HEATERS OR CONTROLS

 

UNIT SIZE

 

024005

024075

024011

 

030005

030075

030011

 

 

RATINGS & PERFORMANCES

 

 

 

 

 

 

 

 

 

 

Nominal Capacity (Btuh)*

 

24,000

24,000

24,000

 

30,000

30,000

30,000

 

 

Nominal Airflow (CFM)

 

 

870

 

 

 

1080

 

 

 

Electric Heating Output (kw @240v)

 

5.0

7.5

11.0

 

5.0

7.5

11.0

 

 

Electric Heating Capacity (MBH @208/230v)

14.0/16.9

20.4/24.7

29.4/35.7

 

14.3/17.2

20.7/25.0

29.7/36.0

 

 

ELECTRICAL

 

 

 

 

 

 

 

 

 

 

Unit Volts-Phase (60 Hz)

 

208/230—1

208/230—1

208/230—1

 

208/230—1

208/230—1

208/230—1

 

 

Operating Voltage Range

 

187—253

187—253

187—253

 

187—253

187—253

187—253

 

 

Internal Circuit Protection

 

 

 

 

None

 

 

 

 

Full Load Amps

 

18.1/20.0

27.1/30.0

39.8/44.0

 

18.1/20.0

27.1/30.0

39.8/44.0

 

 

Minimum Ampacity for Wire Sizing

 

24.5/26.9

35.8/39.4

51.6/56.9

 

25.2/27.5

36.4/40.0

52.3/57.5

 

 

Minimum Wire Size†

 

10/10

8/8

6/6

 

10/10

8/8

6/6

 

 

Maximum Wire Length (Ft)†

 

112/112

117/117

122/122

 

112/112

117/117

125/125

 

 

Maximum Fuse Size (Amps or Ckt Bkr)

 

25/30

40/40

60/60

 

30/30

40/40

60/60

 

 

Control Transformer 24V (Va)

 

 

 

 

40

 

 

 

 

INDOOR COIL

 

 

 

 

 

 

 

 

 

 

Rows & Fins Per In.

 

 

 

3 & 14

 

 

 

 

Height x Width (In.)

 

 

18 x 17.8

 

 

 

22 x 17.8

 

 

 

Face Area (Sq Ft)

 

 

2.23

 

 

 

2.73

 

 

 

R-22 Refrigerant Metering Device-FF1DNA

 

 

Check-Flo-Rater

 

 

 

 

R-22 Refrigerant Metering Device-FF1DNE

 

 

 

TXV

 

 

 

 

Piston Number‡

 

 

63

 

 

 

70

 

 

 

Condensate Drain Connection (Pri-Sec)

 

 

 

3/4 FPT

 

 

 

 

INDOOR BLOWER & MOTOR

 

 

 

 

 

 

 

 

 

 

Wheel Diameter x Width (In.)

 

 

 

10 x 6

 

 

 

 

Filter Size—Cleanable (In.)

 

 

 

16 x 20 x 1

 

 

 

 

Blower Motor HP

 

 

1/5

 

 

 

1/3

 

 

 

Blower Motor Speeds & Type

 

 

 

2 (PSC)

 

 

 

 

Full Load Amps

 

 

1.5

 

 

 

2.0

 

 

 

OPTIONAL EQUIPMENT (P/N’s)

 

 

 

 

 

 

 

 

 

 

Louvered Wall Panel with Frame

(6 Pack)

 

 

KFBLG0106LGL

 

 

 

 

Electric Heat Package

 

 

See ‘‘Optional Field-Installed Electric Heat Packages’’ Table

 

 

* Rated in accordance with U.S. Government DOE test procedures and/or ARI Standard 210/240-94.

Use copper wire only. Use 75°C in this application. When using non-metallic (NM) sheathed cable, wire size required should be based on that of 60°C con-

ductors, instead of wire sizes shown in table above per NEC 1996 Article 336-30. Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%.

Check outdoor unit for required piston size.

††018 Size with 11-kw heater not approved for use with heat pumps.

—5—

Page 5
Image 5
Bryant FF1DNA, FF1DNE manual Specifications, 024005 024075 024011 030005 030075 030011