SPECIFICATIONS

 

UNITS WITHOUT ELECTRIC HEATERS OR CONTROLS

 

 

UNIT SIZE

 

0180

 

0240

 

0300

RATINGS & PERFORMANCES

 

 

 

 

 

 

Nominal Capacity (Btuh)*

 

18,000

 

24,000

 

30,000

Nominal Airflow (CFM)

 

650

 

870

 

1080

ELECTRICAL

 

 

 

 

 

 

Unit Volts-Phase (60 Hz)

 

208/230—1

 

208/230—1

 

208/230—1

Operating Voltage Range

 

187—253

 

187—253

 

187—253

Internal Circuit Protection

 

 

 

None

 

 

Minimum Ampacity for Wire Sizing

 

 

 

 

 

Minimum Wire Size†

 

 

14

 

 

Maximum Fuse Size (Amps or Ckt Bkr)

 

 

15

 

 

Control Transformer 24V (Va)

 

 

 

 

 

INDOOR COIL

 

 

 

 

 

 

Rows & Fins Per In.

 

2 & 14

 

 

3 & 14

Height x Width (In.)

 

 

18 x 17.8

 

22 x 17.8

Face Area (Sq Ft)

 

 

2.23

 

2.72

R-22 Refrigerant Metering Device–FF1DNA

 

 

Check-Flo-Rater

 

 

R-22 Refrigerant Metering Device–FF1DNE

 

 

TXV

 

 

Piston Number‡

 

55

 

63

 

70

Condensate Drain Connection (Pri-Sec)

 

 

 

3/4 FPT

 

 

INDOOR BLOWER & MOTOR

 

 

 

 

 

 

Wheel Diameter x Width (In.)

 

 

 

10 x 6

 

 

Filter Size—Cleanable (In.)

 

 

 

16 x 20 x 1

 

 

Blower Motor HP

 

1/12

 

1/5

 

1/3

Blower Motor Speeds & Type

 

2 & PSC

 

2 & PSC

 

2 & PSC

Full Load Amps

 

0.7

 

1.5

 

2.0

OPTIONAL EQUIPMENT

 

 

 

 

 

 

Cooling Control Relay-Transformer Package

 

 

KFDCC0101DCC

 

 

(with TDR)

 

 

 

 

 

 

 

 

 

 

 

Louvered Wall Panel with Frame

(6 Pack)

 

 

KFBLG0106LGL

 

 

Electric Heat Package

 

See ‘‘Optional Field-Installed Electric Heat Packages’’ Table

 

 

 

UNITS WITH FACTORY-INSTALLED ELECTRIC HEATERS OR CONTROLS

 

 

SIZES

 

018005

 

018075

 

018011††

RATINGS & PERFORMANCES

 

 

 

 

 

 

Nominal Capacity (Btuh)*

 

18,000

 

18,000

 

18,000

Nominal Airflow (CFM)

 

650

 

650

 

650

Electric Heating Output (kw @240v)

 

5.0

 

7.5

 

11.0

Electric Heating Capacity (MBH @208/230v)

13.5/16.3

 

19.9/24.2

 

28.9/35.1

ELECTRICAL

 

 

 

 

 

 

Unit Volts-Phase (60 Hz)

 

208/230—1

 

208/230—1

 

208/230—1

Operating Voltage Range

 

187—253

 

187—253

 

187—253

Internal Circuit Protection

 

 

 

None

 

 

Full Load Amps

 

18.1/20.0

 

27.1/30.0

 

39.8/44.0

Minimum Ampacity for Wire Sizing

 

23.5/25.9

 

34.8/38.4

 

50.6/55.9

Minimum Wire Size†

 

10/10

 

8/8

 

6/6

Maximum Wire Length (Ft)†

 

112/112

 

118/118

 

125/125

Maximum Fuse Size (Amps or Ckt Bkr)

 

25/30

 

35/40

 

60/60

Control Transformer 24V (VA)

 

 

40

 

 

INDOOR COIL

 

 

 

 

 

 

Rows & Fins Per In.

 

 

2 & 14

 

 

Height x Width (In.)

 

 

 

18 x 17.8

 

 

Face Area (Sq Ft)

 

 

2.23

 

 

R-22 Refrigerant Metering Device–FF1DNA

 

 

Check-Flo-Rater

 

 

R-22 Refrigerant Metering Device–FF1DNE

 

 

TXV

 

 

Piston Number‡

 

 

55

 

 

Condensate Drain Connection (Pri-Sec)

 

 

 

3/4 FPT

 

 

INDOOR BLOWER & MOTOR

 

 

 

 

 

 

Wheel Diameter x Width (In.)

 

 

 

10 x 6

 

 

Filter Size—Cleanable (In.)

 

 

 

16 x 20 x 1

 

 

Blower Motor HP

 

 

1/12

 

 

Blower Motor Speeds & Type

 

 

 

2 (PSC)

 

 

Full Load Amps

 

 

0.7

 

 

OPTIONAL EQUIPMENT

 

 

 

 

 

 

Louvered Wall Panel with Frame

(6 Pack)

 

 

KFBLG0106LGL

 

 

Electric Heat Package

 

See ‘‘Optional Field-Installed Electric Heat Packages’’ Table

See notes on page 5.

 