T874 MULTISTAGE THERMOSTATS AND Q674 SUBBASES
71 60-24858
Table 9. Q674 Subbase Cross Reference.
Model
Number Fig.
No. Description Q674 Trade
Replacement Remarks
Q674A S
y
stem: HEAT-AUTO-COOL; Fan: AUTO-ON
A1001 71 Standard OEM. Q674A1019
A1019 71 TRADELINE® model; used with T874A-D. Q674A1019
A1035 71 Obsolete. Trane part no. BAS-0435; used with T874A-D. Q674A1019
A1043 71 Hone
y
well lo
g
o; TRADELINE model; Q674A1019
A1050 71 Obsolete. Standard OEM. Q674A1043
Q674B S
y
stem: HEAT-OFF-COOL; Fan: AUTO-ON
B1000 45 Standard OEM; used with T874C1570, C1695, C1703,
D1843; used in Y594C1363. Q674B1034
B1018 44 Standard OEM; used with T8 74B1035, D1082; used in
Y594B1026, D1016. Q674B1018
B1026 45 Obsolete. S
y
stem: HEAT-OFF-RESET-COOL. Q674B1034
B1034 45 TRADELINE Q674B1034
B1042 47 Obsolete. Used with T874R1004, R1509; used in
Y594R1029, R1334. Y594R1243aWirin
g
differences
(
old=new
)
:
W1=W2.
B1059 45 Obsolete. Factor
y
installed RC-RH
j
umper; used with
T874C1059; used in Y594C1256. Q674B1034 Field wire RC-RH.
B1075 46 Auto fan in heatin
g
and coolin
g
mode; used with
T874B1035, C1000, D1082; used in Y594D1040. Q674B1075
B1083 51 Obsolete. Carrier part no. HH93AZ178; factor
y
installed RC-RH
j
umper. Q674B1075aOne s
y
stem transformer onl
y
.
B1091 45 Obsolete. Carrier part no. HH93AZ184; factor
y
installed RC-RH
j
umper. Q674B1034
B1109 47 Obsolete. Addison heat pump; used with T874R1012. Y594R1243aWirin
g
differences
(
old=new
)
:
W1=W2.
B1117 44 Obsolete. Carrier part no. HH93AZ180; factor
y
installed RC-RH
j
umper. Q674B1018a
B1125 53 Obsolete. York part no. 2TB04700324A; used with
T874D1041. Q674B1075aJumper RC-RH; replacement
has no LOCKOUT LED.
B1133 48 Obsolete. Includes FILTER LED; used with
T874D1082; used in Y594D1156. Q674B1018
B1141 51 Trane part no. BAY28X185; automatic fan operation in
heat and cool mode. Q674B1075 Set T874 H1 anticipator for
combined load of heat rela
y
and fan rela
y
.
B1158 50 Obsolete. Used with T874G1071. T874C1018/
Q674B1018a
W1-Y1 and RH-RC
j
umpers
re
q
uired.
B1166 249 Carrier part no. HH93AZ179; factor
y
installed RC-RH
j
umper; LOCKOUT LED; used with T874C1075
(
HH07AT170
)
.
Y594C1421 or
Q674B1075a
Replacement onl
y
re
q
uires
one transformer and has no
LOCKOUT LED.
B1190 52 Obsolete. Wards special; factor
y
installed RH-RC and
F-W3
j
umpers; used with T874C1372. Gas Furnace:
Q674B1034
Electric Furnace:
Q674B1075
B1208 187 Obsolete. Used with T874C1422. None
B1216 54 Used with T874W1015 and C815A1005; used in
Y594W1014. Q674B1216
B1224 49 Obsolete. Lennox part no. 25F7301; four LEDs; used
with T874C1430. Q674B1034 Replacement has no LEDs.
aBoth the thermostat and subbase must be repl aced.