MODEL 2S

 

SINGLE-SPEED

THERMOSTAT

EASY SELECT

HEAT PUMP

 

TERMINAL BOARD

 

MODEL 2S

TYPICAL

TWO-SPEED

 

 

DH

J1

 

 

 

 

 

 

 

 

JUMPER

 

THERMOSTAT

FAN COIL

HEAT PUMP

24 VAC HOT

R

R

R

 

 

 

 

 

 

 

24 VAC HOT

R

R

 

R

FAN

G

G

 

 

 

 

 

 

 

 

 

 

 

FAN

G

G

 

 

COOL/HEAT

Y/Y2

Y/Y2

 

Y

 

 

 

 

 

STAGE 1

 

 

REMOVE

 

HEAT STAGE 3 W/W1

W2

 

W2

HEAT STAGE 2

W/W1

W1

 

 

J2 JUMPER

 

 

 

 

 

 

 

 

 

FOR HEAT

 

COOL/HEAT

Y/Y2

W3

 

 

HEAT STAGE 3 Y1/W2

W2

STAGING

W2

 

 

 

STAGE 2

 

E

 

Y2

 

 

 

 

 

RVS COOLING O/W2

 

 

RVS COOLING O/W2

O

 

O

 

 

O

 

 

 

Y

*

 

 

 

 

 

COOL/HEAT

Y1/W2

 

 

 

Y1

 

 

 

 

 

 

 

 

 

STAGE 1

 

 

 

Y1

 

 

 

 

 

 

 

 

 

W3

24 VAC COMM

C

C

 

C

 

 

 

 

 

 

 

 

 

24 VAC COMM

C

C

 

C

N/A

B

 

 

 

 

 

 

 

 

 

 

 

 

N/A

B

 

 

 

OUTDOOR

S1

 

See notes 3, 4, and 8

 

 

 

 

 

SENSOR

 

 

OUTDOOR

S1

 

 

 

 

 

 

 

 

 

 

CONNECTION

S2

 

 

 

SENSOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONNECTION

S2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See notes 3, 7, 8, 9, and 11

 

ON

 

 

SUGGESTED DIP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH SETTINGS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SUGGESTED DIP

 

 

 

A B C

D

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH SETTINGS

 

 

OFF OFF OFF

ON

A98497

 

A B C D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 14ÐSingle-Speed Heat Pump

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF OFF OFF OFF

 

 

 

A98496

with Variable-Speed Fan Coil (FK, FV) and Special 3-Stage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 13ÐTwo-Speed Heat Pump

 

 

 

 

 

 

 

 

 

 

Electric Heat

 

 

 

with Typical Fan CoilÐModel 2S Thermostat

 

 

 

 

 

 

 

ÐModel 2S Thermostat

 

 

MODEL AC

 

SINGLE-SPEED

 

 

MODEL HP

 

 

 

SINGLE-SPEED

 

THERMOSTAT

EASY SELECT

AIR CONDITIONER

 

THERMOSTAT

 

 

EASY SELECT

AIR CONDITIONER

 

 

 

 

 

 

 

 

 

 

TERMINAL BOARD

 

 

 

 

 

 

 

 

 

 

 

TERMINAL BOARD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DH

 

 

J1 JUMPER

 

 

 

 

 

 

 

 

 

 

 

 

24 VAC HOT

 

 

 

R

 

 

 

R

 

 

 

 

 

 

 

 

 

 

HEAT STAGE 1

W/W1

 

 

 

W1

 

J2 JUMPER

 

 

 

 

 

 

 

 

 

 

 

 

N/A

 

 

 

 

 

 

 

W2

 

 

 

 

 

 

 

 

 

 

O/W2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAN

 

 

 

G

 

 

 

G

 

 

N/A

 

 

 

 

 

 

 

 

 

 

 

Y1/W2

 

 

 

Y1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOL STAGE 1

Y/Y2

 

 

Y/Y2

 

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24 VAC COMM

 

 

 

C

 

 

 

C

 

C

N/A

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR

 

 

 

S1

 

 

 

 

 

 

See notes 1 and 8

 

 

 

 

 

 

 

 

 

SENSOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONNECTION

 

 

 

S2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DH

 

 

J1

 

 

 

 

 

 

 

 

 

 

 

 

24 VAC HOT

 

 

 

R

 

 

 

R

JUMPER

 

 

 

 

 

 

 

 

FAN

 

 

 

G

 

 

 

G

 

 

HEAT STAGE 1

 

 

 

 

 

 

 

 

 

 

REMOVE

 

 

W/W1

 

 

 

W1

 

J2 JUMPER

 

 

 

 

 

 

 

 

 

 

 

 

FOR HEAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STAGING

 

HEAT STAGE 2

O/W2

 

 

 

W2

 

 

COOL STAGE 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y/Y2

 

 

Y/Y2

 

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y1

 

 

N/A

 

Y1/W2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24 VAC COMM

 

 

 

C

 

 

 

C

 

C

N/A

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR

 

 

 

S1

 

 

 

 

 

 

See notes 2 and 8

 

 

 

 

 

 

 

 

 

SENSOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONNECTION

 

 

 

S2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

ON

 

 

 

 

 

 

 

SUGGESTED DIP

 

 

 

 

 

 

 

SWITCH SETTINGS

 

 

 

A

B

C

D

A

B

C

D

SUGGESTED DIP

SWITCH SETTINGS

OFF OFF OFF OFF

OFF OFF ON OFF

A98498

A98499

Fig. 15ÐSingle-Speed Air Conditioner with Variable-Speed Fan Coil (FK, FV)

ÐModel AC Thermostat

Fig. 16ÐSingle-Speed Air Conditioner with Variable-Speed Fan Coil (FK, FV)

ÐModel HP Thermostat

Ð10Ð

Page 10
Image 10
Bryant TSTAT instruction manual → ÐSingle-Speed Heat Pump