TABLE 2ÐPROGRAMMABLE THERMOSTAT QUICK REFERENCE

 

 

 

 

 

 

 

 

 

 

THERMOSTAT OUTPUT

 

 

 

 

TSTAT Model

 

AC/HP

Staging

24v

Common

Fan

Heat

Heat

Heat Stage 3

Heat Stage 4

Cool Stage 1

Cool

Reversing Valve

 

Outdoor Unit

Configuration

Configuration

 

Hot

Stage 1

Stage 2

Stage 2

 

 

 

(Switch C)

(Switch D)

 

 

 

 

 

 

 

 

 

 

Ð6Ð

AC01-B

AC

EITHER

EITHER

R

C

G

W/W1

N/A

N/A

N/A

Y/Y2

N/A

N/A

HP01-B

HP

OFF

EITHER

R

C

G

W/W1

W/W1

N/A

N/A

Y/Y2

N/A

O/W2

 

Y/Y2

 

HP01-B

AC

ON

EITHER

R

C

G

 

O/W2

N/A

N/A

Y/Y2

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2S01-B

2-Speed AC

ON

EITHER

R

C

G

W/W1

O/W2

N/A

N/A

Y1/W2

Y/Y2

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2S01-B

2-Speed HP

OFF

OFF

R

C

G

Y1/W2

Y/Y2

W/W1

N/A

Y1/W2

Y/Y2

O/W2

 

2S01-B

*1-Speed HP

OFF

ON

R

C

G

Y/Y2

W/W1

Y1/W2²

W/W1, Y1/W2

Y/Y2

N/A

O/W2

²Y1/W2 is on without W/W1

AC = Air conditioner, HP = Heat pump, 2S = 2-speed, N/A = Not applicable, * = Intelligent Heat option Model Numbers: TSTAT--PAC01-B, TSTAT-PHP01-B, TSTAT--P2S01-B

Page 6
Image 6
Bryant TSTAT instruction manual → Ðprogrammable Thermostat Quick Reference, Ð6Ð