Bryston owner manual BDA-1 FEATURES, input selection, Power Considerations

Models: BDA-1

1 4
Download 4 pages 4.48 Kb
Page 1
Image 1
BDA-1 EXTERNAL DAC

BDA-1 EXTERNAL DAC

OWNER’S MANUAL

The Bryston BDA-1 is a State-of-the-Art external Stereo digital to analog converter using fully discrete analog class-A propri- etary Bryston amplifier circuits.

BDA-1 FEATURES:

Dual 192K/24Bit Crystal DAC’s (CS-4398’s)

Separate analog and digital linear power supplies

Discrete Class A analog output stage

Over-sampling

Synchronous up-sampling (176.4K/192K)

Independent Analog and Digital signal paths

Eight digital audio inputs:

1x USB,

4x SPDIF (co-axial wire)

2x optical (TOSLINK)

1x AES/EBU

Sample rates: 32KHz, 44.1KHz, 48KHz, 88.2KHz, 96KHz, 176.4KHz, 192KHz

16-24Bit PCM, 16Bit 32K-48K USB

Fully Differential Balanced XLR and Unbalanced RCA Stereo outputs.

Transformer coupled SPDIF and AES/EBU Digital inputs.

SPDIF COAX Bypass Loop Output

Software upgradable via RS232 port

Optional Remote Control

Remote 12 Volt On/Off Trigger

Compatible with CD Drives, Sound Cards, Computers, Music

Servers.

Cosmetically matches C-Series BP26, MPS2, BCD-1, etc

input selection:

The digital signal first arrives at the BDA-1 via either the SPDIF co-ax, TOSLINK optical, AES/EBU or USB input. These are the normal digital outputs from a CD Drive, Sound Card, Computer, Music Server etc. One of these 8 inputs is selected by either the front panel push button switches or the infra-red remote control.

OPTIONAL BR2 REMOTE CONTROL:

The BR2 infra-red remote control offered for use with the BDA-1 is a multi-function remote capable of operating not only the BDA-1, but also the BCD-1 CD player and many Bryston preamps and integrated amplifiers such as the BP26, BP6, BP16, B60R and B100. For more information see the BR2 Owner’s Manual.

POWER CONSIDERATIONS:

In general, if your BDA-1 has a three prong grounded line cord you can reduce the possibility of local ground loops which could cause hum or noise in the system by plugging its line cord into the same wall outlet next to the power amp and other equip- ment in your system.

UNDER-VOLTAGE INDICATOR:

The BDA-1 contains an under-voltage detection circuit which will illuminate the red Up-Sample LED if the connected AC sup- ply voltage is approximately 20% or more below nominal (e.g. <96vac for a 120vac unit, or <185vac for a 230vac unit). When such an under-voltage condition exists the BDA-1 will not power up and the only LED to be illuminated will be the red Up-Sample LED.

FUSES & ELECTRICAL SAFETY:

The BDA-1 contains a single fuse located inside the unit. IF it should become necessary to replace this fuse we recommend that you seek the assistance of qualified service personnel. If you decide to change the fuse yourself we advise the following:

1st)

Turn off the BDA-1

2nd)

Disconnect ALL cables from the rear of the BDA-

 

1, especially the power cord.

3rd)

Remove the 10 screws securing the top cover to

 

remove the top cover panel

4th)

Locate the 5x20mm glass fuse on the CD1-PM

 

circuit board (near the IEC power inlet) of the

 

BDA-1. Replace a blown fuse only with the same

 

type and value of fuse. All fuses are rated 250V

 

For 100 volt models fuse value is F 250mA L

 

For 120 volt models fuse value is F 250mA L

 

For 230 volt models fuse value is F 125mA L

 

For 240 volt models fuse value is F 125mA L

5th)

Replace the top panel and all 10 screws and

 

reconnect all necessary cables

FEATURES, CONTROLS & CONNECTIONS:

1:SAMPLE RATE LED Array: (2 columns X 4 rows).

Indicates the sample rate of the selected input and whether or not it is locked.

2:UP-SAMPLE: Engages up-sampling such that incoming sample rates of 32K, 48K or 96K sps will be up-sampled to 192K (LEDs ~ see above ~ light green), and 44.1K and 88.2K sps will be up-sampled to 176.4K (LEDs light red) to allow for optimal DAC performance.

N.B. The Up-Sample LED may also be used to indicate an under-voltage situation wherein the AC supply voltage is approx. 20% or greater below nominal. See UNDER- VOLTAGE INDICATOR section above.

3:OPTO INPUTS: There are two TOSLINK inputs for optical digital audio.

4:SPDIF INPUTS: There are four SPDIF inputs for coaxial cable connections. Two inputs have RCA (phono) connectors, and two have BNC connectors.

5:AES/EBU INPUT: There is one AES/EBU (Audio Engineering Society/European Broadcasting Union) fully balanced input using a 3 pin XLR female connector for a twisted pair wire connec- tion of a digital audio signal.

6:USB input: There is a single USB, revision 1.1 compli- ant, input. When connecting to a PC it may be necessary to direct the digital audio stream from your computer through its USB port to the BDA-1. To do so, click on your PC’s START menu then select CONTROL PANEL > SOUNDS & AUDIO DEVIC- ES > AUDIO and ensure that the Bryston BDA-1is selected.

N.B. Put the BDA-1 in STANDBY before connecting or discon- necting a USB cable. DO NOT HOT SWAP!

7:POWER SWITCH ~ STANDBY LED INDICATOR:

When the LED above the power switch is lit red the unit is