REPLACING FUSES IN THE MPS2 POWER SUPPLY
CAUTION: These service instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.
All fuses are 5mm x 20mm, time lag type and are accessible only by removing the top cover. When replacing fuses, disconnect the power cord before opening the unit!
Recommended replacement fuses: |
| |
100V~ models: T 2.5A L 250v | Littlefuse 218 | 02.5 |
110V~ models: T 2.0A L 250v | Littlefuse 218 | 002 |
120V~ models: T 2.0A L 250V | Littlefuse 218 | 002 |
200V~ models:T 1.25A L 250v Littlefuse 218 | 1.25 | |
220V~ models: T 1A L 250v | Littlefuse 218 | 001 |
230V~ models: T 1A L 250v | Littlefuse 218 | 001 |
240V~ models: T 1A L 250v | Littlefuse 218 | 001 |