Bunn 2 operation manual Disassembly & Cleaning

Models: 2

1 3
Download 3 pages 44.87 Kb
Page 1
Image 1
DISASSEMBLY & CLEANING

USE & CARE INSTRUCTIONS for ULTRA-2 COLD DRINK DISPENSER WITH PAF DISPENSER

NOTICE - This guide is for quick reference only and is not intended to replace the information in the Operation Manual!

DISASSEMBLY & CLEANING

Empty all product from the ULTRA hoppers before proceeding!

1.Open the Cabinet Door and allow the support arms to lock in place.

2.Pull the Mixing Cham- ber out of the Whipper Chamber.

3. Twist the Whipper Chamber clockwise and pull it off the Whipper Chamber Receptacle.

4.Pull the Frother off the Motor Shaft. Notice the flat keyway on the shaft and the matching keyway inside the Frother. It is important that these two keyways are lined up when reassembling.

5.Twist Whipper Cham- ber Receptacle clockwise and pull it off the Motor Shaft.

6.Slip the O-ring off the Whipper Chamber Recep- tacle and remove the shaft seal.

7.Wash components in a mild solution of dish de- tergent using a bristle brush.

8.Slide PAF assembly back until it latches before removing ULTRA Hop- pers.

9.Depress the Hopper Lock Plunger, lift slightly.

10.Pull the Hopper as- sembly forward and re- move.

11.Pull the Auger from the Cooling Drum.

12.Remove the Hopper Seal from the flange on the Cooling Drum.

13. CAUTION: Faucet Valve is under spring ten- sion. Spread one side of the Handle first, then the other and disconnect from the Hopper.

14.Carefully slide Valve up to remove Spring and Faucet Seal. Extra care should be taken when handling the Seal to pre- vent damage.

15.Remove the Auger Nose Bushing from inside the front of the Hopper.

35113.0000A 11/02 ©2002 Bunn-O-Matic Corporation