![THOROUGH CLEANING OF THE PAF HOPPER (Once a week)](/images/new-backgrounds/63092/630925x1.webp)
26. Slide PAF assembly | 27. Reassemble and in- | 28. Position the Faucet | 29. Slide the Faucet Valve |
forward. | stall all PAF parts. Close | Seal and Return Spring in | assembly into place on |
| Door. | the Faucet Valve. | the Hopper. |
31.Install the Drip Tray and Cover.
30.Press down on the Valve to compress the Spring. Position the Fau- cet Handle over the Fau- cet Valve one side at a time and snap into place on the Hopper.
THOROUGH CLEANING OF THE PAF HOPPER (Once a week)
1.Open the Cabinet Door and allow the support arms to lock in place.
6. Remove the Auger Drive Shaft by removing Retaining Clip from Auger Drive Shaft.
2.Remove the Hopper/ Base Assembly from the Cabinet. Remove the Cover and empty the con- tents.
7.Wash all components in a mild solution of dish deter- gent using a bristle brush when needed. Rinse and dry each item thoroughly before reassembling.
3.Pull the Ejector Elbow off the Hopper Base. Re- move the Slide Gate from the Ejector Elbow.
4. Remove the Wiper Blade and Drive Gear by removing the Retaining Ring from the Wiper Blade Shaft.
5.Remove Auger by pull- ing it out the front of Hop- per Base.
35113 111302