INITIAL fill & heat

1.Turn on the water supply and connect the dispenser to the power source.

2.Water will automatically flow into the tank to the proper level and then shut-off. This will take less than ten minutes.

3.When the tank is full of water, open the front door and place the ON/OFF/NIGHT switch in the “ON” (up- per) position. A tank full of cold water will take approximately eighty minutes for the water to heat on 120 volt versions, and forty minutes on 120/240 volt versions.

4.Fill the hopper(s) with the dry product to be dispensed.

LIQUID LEVEL CONTROL

The system automatically maintains the hot water tank’s level by energizing the refill solenoid when the water level drops below the liquid level probe. If the system has not successfully refilled in 10 minutes, a refill error occurs. When a refill error occurs, the refill solenoid is de-energized. Once the cause of the refill error has been investigated and cured, the system can be reset by either disconnecting (for at least 5 seconds) and then reconnecting the power to the machine, or by entering one of the program modes (see Programming Modes.)

RINSE TIMER

The dispenser is shipped from the factory with the rinse timer disabled. To enable the rinse timer, refer to Programming the Dispenser and select yes in the “Rinse Alarm ?” screen; set timer to the desired time and exit the programming mode.

When enabled, the rinse timer automatically keeps track of the time since the dispenser was last run through a rinse sequence. If the dispenser detects that a rinse sequence has not been run for the desired time, a message will appear on the LCD display. If the Lockout is set, after an additional 4 hours, a rinse cycle has still not been run, the LCD display will display a message, and the hopper drives will be disabled until a rinse sequence has been run.

RUNNING A RINSE SEQUENCE

1.Place the Normal/Program/Rinse switch (page 9) in the “rinse” position.

2.Sequentially at each position, press all of the dispense switches. The dispenser will run for 10 seconds with the hopper(s) disabled.

3.As each position is rinsed, the LCD display will show which position is being rinsed and count down from 10 seconds.

4.After all positions have been rinsed, return the Normal/Program/Rinse switch to the “Normal” position.

DISPENSER USE - Self Serve

1.Simply place a cup on the drip tray beneath the desired dispensing tip.

2.Press the button to froth and dispense the beverage.

3.Release the button when the cup is approximately 3/4 full and allow the mixing chamber to drain. Note - The mixing chamber must drain at the end of each dispense.

DISPENSER USE - Portion Control

1.Simply place a cup on the drip tray beneath the desired dispensing tip.

2.Select the appropriate button for the cup size under the dispense tip, press momentarily, then release.

3.Let the mixing chamber completely drain before removing cup.

5