GLOSSARY
TANK TEMP XXX°
READY TEMP XXX°
SET CUP SIZE
EXMPL TIME
DISPENSE TO ADD
REPEAT SAVE
DRINK STRENGTH
XX° CAL XX°
235 REFILL 155
CAL WATER ?
PRESS DISPENSE
CAL POWDER ? PRESS DISPENSE
| Auger Delay |
|
.XX sec | (+) |
CAL HOPPER ?
NOYES
LOW POWDER LOCK ?
NO EXIT YES
DISPENSE LOCKOUT
NO EXIT YES
RINSE ALARM ?
NO EXIT YES
HEAD 1 DISABLE ?
NO EXIT YES
Adjust tank temperature (190° F maximum)
Adjust minimum tank ready temperature for lockout (185° maximum)
Select setting cup size by Time (seconds) or by Example (Portion Control models only)
Press same dispense button to top off cup, or press save to lock in dispense time, or, press repeat to erase dispense time and repeat process.
Adjust hopper motor speed for station selected
Calibrate temperature probe
Set refill probe threshold
Calibrates dilution water flow rate in station selected
Calibrates powder dispense rate for hopper in station selected
Set delay start of hopper after dilution valve opens in station selected
Calibrates hopper level sensor in station selected Hopper must be at least half full to calibrate
Enables lockout of dispensing when low hopper level is detected
Enables lockout of dispensing if below minimum water temperature
Enables rinse alarm
Disables all functions and dispensing for station selected
SET PASSWORD ?
AUDIBLE ALARM ? NO EXIT YES
DISABLE MESSAGES ? NO EXIT YES
ENABLE ADS ?
NO EXIT YES
ENTER ASSET # ? EXIT YES
ENABLE SERVICE #
NO EXIT YES
ENABL EngergySavr
NO EXIT YES
TEST SWITCHES ? Use Switch To Test
TEST HEATER ? EXIT YES
TEST REFILL ? EXIT YES
TEST HOT WATER ? EXIT YES
TEST AUGERS ? DISPENSE TO TEST
TEST DISP HEADS DISPENSE TO TEST
DISPLAY USAGE ? EXIT YES
FACTORY DEFAULTS
NOYES
Allows password to be set to prevent altering setup functions
Turns on audio alarm
Disables function that displays fault messages on LCD door display
Enables “ADS” to be displayed on LCD door display
Enter asset number of machine
Enables service agent telephone number to be displayed
Enables energy saver mode
Allows testing of dispense switches
Allows manually activating tank heater
Allows manually activating refill valve
Allows manually activating hot water valve (optional)
Allows manually activating hopper motors
Allows manually activating dispense valves & whipper motors
Displays amount dispensed
Resets all functions to factory defaults, and password to 0
7 | 37510 113004 |
|