Bunn CDS-3 TROUBLESHOOTING cont, Problem, Probable Cause, Remedy, B Remove the strainer and check

Models: CDS-2 CDS-3

1 34
Download 34 pages 32.1 Kb
Page 10
Image 10

TROUBLESHOOTING (cont.)

 

 

 

PROBLEM

PROBABLE CAUSE

REMEDY

Powder Auto-Fill will not dispense

1. No water

Water lines and valves to the dis-

product

 

 

penser must be open and free of

 

 

 

obstructions.

 

2.

No power or incorrect voltage to

Check that the power cord is con-

 

the dispenser.

nected to the CDS dispenser and for

 

 

 

voltage from the CDS dispenser.

 

3.

Dispense Solenoid Valve

Refer to Service- Dispense Solenoid

 

 

 

Valve for testing procedures. See

 

 

 

page 32

 

4.

Control Board and Probe

Refer to Service- Control Board and

 

 

 

Probe for testing procedures. See

 

 

 

page 18

 

5.

Auger Drive

Refer to Service- Auger Drive for

 

 

 

testing procedures. See page 13

 

6.

Transformer

Refer to Service- Transformer for

 

 

 

testing procedures. See page 26

 

7.

Water Strainer (Optional)

A) Direction of flow arrow must be

 

 

 

pointing towards dispenser.

 

 

 

B) Remove the strainer and check

 

 

 

for obstructions. Clear or replace.

Dripping from dispense tip

1. Dispense Solenoid Valve

Remove dispense valve and clear

 

 

 

any obstructions. Rebuild or replace

 

 

 

the valve if necessary. Seepage 32

Water flows continuously

1. Control Board and Probe

Refer to Service- Control Board and

 

 

 

Probe for testing procedures. See

 

 

 

page 18

 

2.

Dispense Solenoid Valve

Refer to Service- Dispense Solenoid

 

 

 

Valve for testing procedures. See

 

 

 

page 32

10

29793 061599

 

Page 10
Image 10
Bunn CDS-3, CDS-2 service manual TROUBLESHOOTING cont, Problem, Probable Cause, Remedy, B Remove the strainer and check