TROUBLESHOOTING (cont.) |
|
|
|
PROBLEM | PROBABLE CAUSE | REMEDY | |
Powder | 1. No water | Water lines and valves to the dis- | |
product |
|
| penser must be open and free of |
|
|
| obstructions. |
| 2. | No power or incorrect voltage to | Check that the power cord is con- |
| the dispenser. | nected to the CDS dispenser and for | |
|
|
| voltage from the CDS dispenser. |
| 3. | Dispense Solenoid Valve | Refer to Service- Dispense Solenoid |
|
|
| Valve for testing procedures. See |
|
|
| page 32 |
| 4. | Control Board and Probe | Refer to Service- Control Board and |
|
|
| Probe for testing procedures. See |
|
|
| page 18 |
| 5. | Auger Drive | Refer to Service- Auger Drive for |
|
|
| testing procedures. See page 13 |
| 6. | Transformer | Refer to Service- Transformer for |
|
|
| testing procedures. See page 26 |
| 7. | Water Strainer (Optional) | A) Direction of flow arrow must be |
|
|
| pointing towards dispenser. |
|
|
| B) Remove the strainer and check |
|
|
| for obstructions. Clear or replace. |
Dripping from dispense tip | 1. Dispense Solenoid Valve | Remove dispense valve and clear | |
|
|
| any obstructions. Rebuild or replace |
|
|
| the valve if necessary. Seepage 32 |
Water flows continuously | 1. Control Board and Probe | Refer to Service- Control Board and | |
|
|
| Probe for testing procedures. See |
|
|
| page 18 |
| 2. | Dispense Solenoid Valve | Refer to Service- Dispense Solenoid |
|
|
| Valve for testing procedures. See |
|
|
| page 32 |
10 | 29793 061599 |
|