FUNNEL DETECT (optional)

PROGRAMMING THE BREWER (cont.)

FUNNEL DETECT (optional)

This function allows the operator to prevent the start of a brew cycle if a Smart Funnel is not positioned correctly in the funnel rails.

FUNNEL DETECT ?

NO DONE YES

Procedure to set funnel detect:

1.Press and hold the upper right hidden switch until display reads UNITS. Release the switch. Continue to press and release switch until display reads

FUNNEL DETECT.

2.NO or YES should be flashing to indicate the cur-

rent setting.

4.Select YES to prevent brewing if a Smart Funnel is not correctly situated in the rails. If this function is activated and a brew cycle is attempted with the funnel not properly situated, the display will read, FUNNEL NOT IN PLACE, until one is in place.

5.Select NO to allow brewing without a Smart Fun- nel in place. This is selected when brewing with a funnel other than a Smart Funnel (a regular brew funnel).

6.When finished, press and release DONE. This will retain the changes, exit this function screen and advance to the next. Another alternative is to press the ON/OFF switch (either on DUAL brewers) lo- cated on the front switch panel to exit the FUNNEL DETECT and return to the MAIN SCREEN.

SERVICE TOOLS

This function allows the testing of individual com- ponents and the ability to check switches for proper function. This function also tests the Soft Heat server's status on the brewer (in place or removed), and the funnel sensor coil's frequency (diagnostic tool for troubleshooting purposes only).

Testing individual components (outputs):

This will allow the operator to test the operation of individual components and outputs of the brewer. The components that can be individually tested are as follows:

SINGLE Brewers

DUAL Brewers

Brew Valve

Left Brew Valve

Bypass Valve

Left Bypass Valve

Funnel Lock (Optional)

Left Funnel Lock

Refill Valve

Right Brew Valve

Tank Heaters

Right Bypass Valve

Heater Contactor

Right Funnel Lock

 

Refill Valve

 

Tank Heaters

 

Heater Contactor

Procedure to test components (outputs):

1.Place brew funnels into rails on both sides of brewer.

2.Place a server beneath each brew funnel.

3.Press and hold the upper right hidden switch until display reads UNITS. Release the switch. Continue to press and release switch until SERVICE TOOLS appears.

4.Press YES to run tests on various components and outputs within the brewer. Pressing NO will exit this function and advance to the next function screen.

5.The display should read TEST OUTPUTS.

6.Press and release YES. The display should read

LEFT BREW VALVE.

7.To test LEFT BREW VALVE, press ON. If the brew valve is functional, water should run from the left brew side.

8.Press OFF to end flow of water.

9.Press NEXT to advance to the next component to be tested.