PROGRAMMING THE BREWER (cont.)
SERVICE TOOLS (cont.)
the next function screen. Press YES to run tests on various components and outputs within the brewer.
5.The display should read TEST OUTPUTS?.
6.In TEST OUTPUTS screen, press NO. Continue to press and release NO until the display reads TEST
FREQUENCY?.
7.Press and release YES. The display will show the frequency of the sensor coil circuits. This is for diagnostic service use when troubleshooting this circuit.
8.After the coils have been tested, press and release the ON/OFF switch (either on DUAL brewers) located on the front switch panel. This will exit the TEST FREQUENCY function and return to the
MAIN SCREEN.
NOTE: If the operator wishes to test more than one function in the SERVICE TOOLS section (outputs, switches, servers, or coil frequency), it is not necessary to exit the program. Use the flow chart for SERVICE TOOLS to navigate to a particular function.
FACTORY DEFAULTS
This function allows the operator to erase all of the previously entered recipes and ad messages. Factory- set default values will replace all previous settings.
SEL BREWER TYPE?
NOYES
ThermoF SoftHeat
DONE
FACTORY DEFAULTS
NOYES
EXIT
WILL REPLACE ALL
BREW SETTINGS
ARE YOU SURE?
NOYES
EXIT |
|
|
|
| P2312 |
|
|
|
| ||
|
REPLACE
Procedure to set factory defaults:
1.Press and hold the upper right hidden switch until UNITS appears. Release the switch. Press and release the upper right hidden switch until the display reads SEL BREWER TYPE?.
2.Pressing NO in this screen will advance to FACTORY DEFAULTS. Press and release YES. The display should read ThermoF SoftHeat. The selected brewer type will be flashing. When correct brewer type is selected press DONE.
3.The display should now read FACTORY DEFAULTS. Pressing NO in this screen will revert to the MAIN SCREEN. Press YES to replace the defaults. This advances to WILL REPLACE ALL BREWING SET- TINGS. This screen will alternate with ARE YOU SURE?.
4.Pressing NO in the confirmation screen will revert to MAIN SCREEN, without resetting the brewing setups to the defaults. Press YES to load the de- faults. This will then revert to the MAIN SCREEN, and the factory default values will replace all previously entered values. It will NOT reset the summation Brew counter.
Page 36 | 41342 080108 |
|