MAINTENANCE
The Error Log is under the control of internal background maintenance software that automatically escalates an error to a more serious category or retires it. The system tests itself after a repair has been made. If the error condition is corrected, the error may be removed from the Error Log.
Although some errors are automatically retired from the Error Log, they can also be manually retired by entering commands at the SAT. Alarms, conditions that light the alarm LED on the attendant console, can also be manually retired in the same way.
Accessing the Error Log From the SAT
Follow these steps to read any of the tables in the Error Log from the SAT:
1.Confirm that the SAT is properly connected to the CPU/Memory CP administration port.
2.If the SAT has a selectable baud rate, set it to 1200 baud.
3.Be sure that transmission parity is set to none, with the parity bit set to space (0).
Note: For the AT&T Model 703 SAT, four pencil switches under the paper compartment cover are set as follows: switches 1 and 3 to “Off;” switches 2 and 4 to “On.”
4.Turn on the terminal, and press the carriage return key once or twice. On most terminals, this key is <RETURN> or <ENTER>.
5.After communication with the system’ is established, a prompt is displayed:
Enter Password
6.Obtain the password from the system administrator. Enter the password, and press <RETURN>. The main menu is displayed with the prompt: Make one selection from menu
7.Enter 8 (for the SEARCH selection), and press <RETURN>.
8.The SAT displays:
When search is defined type c to search >Action=