APPENDIX F: Administration Error Messages
ERROR MESSAGE
AND DESCRIPTION POSSIBLE SOLUTION
1083:inappropriate request Recheck translations to see if TT
TT generator not installed generator was installed.
1084: inappropriate request Trying to administer a third CAP
system already has two when you are only allowed two.
CAPS
1085:incorrect entry Data parity setting must be between
must be 0-3 if parity, else 0-3. Delay break for STARLAN is
0-1 0-1.
1086:inappropriate request Cannot assign a DID trunk port an
DID trunk can’t have (ID) name. Go to MENU 1 (Port)
Trunk ID ACTION = 90
DATA = “name-not-allowed " for
DID trunk.
1088:entry out of range SMDR billing must be between
data must be 10-255 10-255 seconds
MENU = 4 (System)
ACTION = 53
DATA = 10-255
1089: entry out of range Port number cannot exceed 5 digits.
port can’t exceed 5 digits
1090: at installed max Can only associate 1 data button
-1 data button
with a PDC.
1091: incorrect entry Switched Loop Console call type
data must be 0-7 priority must be between 0-7. See:
MENU = 4 (System)
ACTION = 92
for more information.
1092:incorrect entry You are exceeding the amount of
Trunk ID must be 9
characters that a trunk name (ID)
characters or less can be.
F-8