INSTALLATION
LEGEND :
ZTN76
- GROUND START CP
ZTN77
- LOOP START CP
A-3 TO 1 SPLITTER CABLE (WP-90929,L1)
UPAM -
UNIVERSAL TELEPHONE (PAGING) ACCESS MODULE
P1- PRS-48 POWER SUPPLY
W1
- INSIDE WIRING CABLE (4-PAIR)
NOTES :
1. APPARATUS CODE D-181523 INCLUDES
66E3-25 BLOCK CONNECTOR AND CABLE
B25A 15/DE.
2. APPARATUS CODE 0-181900 INCLUDES UPAM AND
PRS-48 POWER SUPPLY. D-181900 IS REQUIRED
UNLESS ALL OF THE FOLLOWING CONDITIONS EXIST:
PAGING EQUIPMENT IS FCC REGISTERED
PAGING EQUIPMENT DOES NOT REQUIRE A CONTACT
CLOSURE FOR PROPER OPERATION
A TRUNK INTERFACE IS PROVIDED.
Figure 2-59. Paging System Connection to ZTN76 or ZTN77