MAINTENANCE

ERROR MESSAGE

POSSIBLE SOLUTION

 

AND DESCRIPTION

 

 

 

 

 

 

 

 

 

Illegal Instruction: This error is

The Problem could be with the

logged when an illegal instruction

ROM on the CPU/Memory CP. If

is encountered by the CPU.

the problem persists, check or

 

 

 

replace

CP.

 

 

 

 

 

Illegal Interrupt: CPU/Memory CP

The CP may still pass the power-

problem.

 

 

up test for the ROM. Check or

 

 

 

replace the CPU/Memory CF.

 

 

 

Illegal Port Command: (STARLAN

Recoverable; no action required.

Interface CP) This error is an

 

 

 

 

 

 

isolated transient condition.

 

 

 

 

 

 

 

 

Illegal Port Interrupt: (STAR LAN

Normally, this is a isolated

Interface CP) This error is an

transient

condition

that

i s

isolated transient condition.

recoverable; however, if problem

 

 

 

occurs

t o o frequently,

a

 

 

 

permanent

 

alarm

will

be

 

 

 

generated. If

problem

persists,

 

 

 

check or replace CP.

 

 

 

 

 

 

 

 

Internal RAM Failure: Port CP

Check

port

CF.

 

 

error while running background

 

 

 

 

 

 

non-destructive internal RAM

 

 

 

 

 

 

tests .

 

 

 

 

 

 

 

 

 

 

 

 

I n t e r n a l

Sanity

Timeout:

If the reset is not successful,

(STARLAN

Interface

CP) This

reseat board. If the reseat fails,

error resets the CP.

 

replace

the

CP.

 

 

 

 

Invalid Board Message: The port

If the problem persists, check or

CP sent an up-link message that

replace the port CP.

 

 

is not in the expected message

 

 

 

 

 

 

s e t .

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 