APPENDIX E: Administration Codes and Data

Table E-R. Port Options

PORTS, Station/Trunk/Special Port Circuit Board Options

FOR QUALIFIED SYSTEMS TECHNICIANS ONLY

(See Table E-S," Applicable Options " )

ACTION

DESCRIPTION

DATA

32Set CO disconnect time (in 20 msec [0-2540 msec; 500] increments)

33Set end-to-end signaling tone timing (in 20 msec increments)

FOR TN742 AND ZTN78 ONLY:

[20-2540 msec; 340]

FOR ALL OTHER BOARDS:

[0-2540 msec; 60]

34Set end-to-end signaling pause timing (in 20 msec increments)

 

FOR TN742 AND ZTN78 ONLY:

[20-2540 msec; 100]

 

FOR ALL OTHER BOARDS:

[0-2540 msec; 60]

35

Set hybrid balance. Data is balance

[1/0] .

 

t y p e :

1=Resistor;

 

 

0=Resistor/Capacitor.

Trunk ports

 

 

default to 0; station ports default to 1.

[ 1 / 0 ]

36

Set gain; 1 (Gain=3dB) or 0 (Gain=0dB)

37

Set E&M signaling type. Data is

[ 0 - 2 ]

 

signaling type 0 (Type 1 compatible), 1

 

 

(Type V), or 2 (Type l).

 

 

38

Set answer supervision delay timing

[0-51 00 msec; 300]

Warning: The default values in Tables E-Rand E-Smust not be changed without the support and guidance of Tier Ill s t a f f .