APPENDIX E: Administration
Table E-T. PDC Administration (Menu=2)
Codes and Data
ACTION DESCRIPTION DATA
0
Move this station to a new port [CSSPP (new port assignment)]
(moved-to port must be vacant)
1
Display terminal type code [See Table E-C]
2-53
All other See note below.
90
Assign/remove PD. Display ID ["11 characters or less,” or ** to
remove]
Note: Action/data items administrable under PD. (Menu=2) are the same as those
administrable under Port (Menu=1). (See Table E-B.) ‘
Table E-U. High Density Circuit (Menu=3)
ACTION DESCRIPTlON
DATA
1
Board type[746=TN764/767=TN767
2
Error reporting enable [1=enable/O=disable
3
Line compensation
[Select 1-5]
4
Zero code suppression
[0=ZCS/1=B8ZS]
5
Framing mode
[0=D4/1=ESF]
6
Signaling mode
[O=Robbed bit/1=Common Channel
8
Red alarm activation time [0=3 sec./1 =10 sec.]
November 1995