SYSTEM TESTS

2.At any multiline voice terminal, go off-hook, dial the ARS access code, and dial one of the long-distance numbers. Make sure that the call is completed before going on-hook.

3.Repeat Step 2 if additional long-distance numbers must be called.

4.At the SMDR printer (or SAT), verify that the call was placed over the correct trunk group.

5.If not, verify the translations through the SAT.

6.If the SAT was substituting for the SMDR printer, return the SAT to port 1.

Remote Access Test

Make an incoming call through the RA trunk. Use the correct and incorrect Barrier Codes. Check the SMDR,

DGC Test

1.At any voice terminal, go off-hook, dial the CO trunk access code, and dial a DGC listed directory number.

2.At the ringing terminal in the DGC group, go off-hook and verify transmission.

3.Repeat Steps 1 and 2 for each DGC group.

4.Make additional calls to exercise each member of the complete DGC group.

5.Test the DGC dialing announcement (if provided) by making whole group busy or by logging all members of the group out.

6.At any voice terminal, dial the DGC access code and go to Step 2.

System Speed Dialing Test

1.From the SAT, determine which numbers have been translated for System Speed Dialing. (Obtain the list of translated numbers from the System Administrator.)

2.At any voice terminal, go off-hook, dial a system speed calling code. Verify transmission and that correct party was reached.

November 1995

3-7

Page 167
Image 167
ADTRAN 25 manual DGC Test