MAINTENANCE

 

 

 

 

 

 

 

 

 

Table 4-C.

Circuit Pack Voltage–Symptoms

 

 

 

 

 

 

 

 

 

 

Voltage/

 

+5 volts

 

-5 volts

 

-48 Volts

 

 

Circuit Pack (Notes)

 

No+5 V

 

No-5 V

 

No-48 V

 

 

Call Proc. (ZTN82,

x

System Failure

x

EIA Failure

x

ETU Activated

 

 

ZTN1 28) for RI

 

 

 

 

 

 

 

 

Memory (ZTN81,

x

System Failure

-

-

-

-

 

 

ZTN1 27) for RI

 

 

 

 

 

 

 

 

CPU/Memory (ZTN129,

x

System Failure

x

EIA Failure

x

ETU Activated

 

 

for R2, ZTN130

 

 

 

 

 

 

 

 

for R3)

 

 

 

 

 

 

 

 

STARLAN (ZTN84)

x

CP Failure

x

CP Failure

-

-

 

 

Service Ckt (ZTN85

x

System Failure

-

-

-

-

 

 

or ZTN131 (R3)

 

 

 

 

 

 

 

 

Hybrid Line (ZTN79)

x

CP Failure

x

No Voice

x

Station OS

 

 

Tip/Ring (ZTN78)

x

CP Failure

x

No Voice

x

Station OS

 

 

Analog Line (TN742)

x

CP Failure

x

No Voice

x

Station OS

 

 

MET Line (TN735)

x

CP Failure

x

No Voice

x

Station OS

 

 

Loop Start (ZTN77)

x

CP Failure

x

No Voice

x

Trunks OS

 

 

Grd Start (ZTN76)

x

CP Failure

x

No Voice

x

Trunks OS

 

 

DID Trk (TN753)

x

CP Failure

x

No Voice

x

Trunks OS

 

 

Tie Trk (TN760B)

x

CP Failure

x

No Voice

x

Trunks OS

 

 

Aux Trk (TN763)

x

CP Failure

x

No Voice

x

AUX. Eq. OS

 

 

Data Line (TN726)

x

CP Failure

-

-

-

-

 

 

Tone Det (TN748)

x

Tone Failure

-

-

-

-

 

Legend: CP—Circuit Pack ETU—Emergency Transfer Unit OS-Out-of-Service

X—indicates that the voltage is used by the associated CP.

Notes: 1 .Ringing voltage (not shown on table) is used by the ZTN78 and TN742 CPs. Associated stations will not ring if a ringing voltage problem occurs.

2.TN746B same as TN742

3.TN747 same as ZTN76 and ZTN77

4.TN762 same as ZTN79.

4-66

Page 242
Image 242