MAINTENANCE
ERROR MESSAGE
AND DESCRIPTION POSSIBLE SOLUTION
ServiceCircuit Test Failed: Check TDM bus terminator and
Service Circuit demand test failed
cabinet interconnect cables. If the
on the DTMF receivers. problem persists, replace ZTN85
or ZTN131 (R3).
Signaling Lead Fault: Auxiliary Checkwiring of external
Trunk CP is expecting a ground equipment per Figure 4-7.
from external equipment but none
is detected.
SlotConfiguration Error: This condition can be resolved by
(STARLAN Interface CP) This moving the ZTN84 port CP to
error means that another ZTN84 another slot in the carrier.
port CP is on the STARLAN
NETWORK and has the same
physical address.
System Lock-Up: This error is Usually, no action required;
logged by the task supervisor if, however if problem persists,
during scheduling of tasks, no replace CPU/Memory CP.
messages have been read for at
least 60 seconds. This causes a
restart of the system.
System Restart: System locked Check the power supply voltages
up in a software task. The “Port per Figure 4-2. If problem persist,
Number” entry in the log is the the CPU/Memory CP could be
task at fault.
defective.
Translation Memory Test Failed: Check if Cold Start error has
Memory translation checksum test occurred. Reload translations
failed.from tape per the procedure in
Administration Manual. If the
problem persists, check or
replace CPU/Memory CP.