SYSTEM TESTS

MAKE POOLED MODEM TEST CALL

Skip this test if the system does not include a TN758 Pooled Modem CP.

This test involves placing a data call from a data terminal connected through an ADU from a data terminal or personal computer connected via a modem (the modem may be part of a terminal connected to System 25 or off premises). Place the call following the dialing procedure required by the modem. When you hear answer tone, transfer the call to data. You should now be able to communicate with the called endpoint.

TEST TRANSFER TO DATA

Perform this test at each voice terminal with a DATA button,

1.Determine which data terminal or personal computer (PC) is associated with the DATA button being tested. Be sure the terminal or PC is turned on.

2.Go off-hook at the voice terminal.

3.Dial the DDC of another data terminal or host computer (be sure the terminal or PC is turned on and idle).

4.When you hear answer tone, press the DATA button and hang up.

5.A call is now established between the associated data terminal and the called terminal. Verify connection by sending a message or logging in at the called end-point.

6.Hit <BREAK> twice within 1 second at one of the data terminals to disconnect the call.

3-11

Page 171
Image 171
ADTRAN 25 manual Make Pooled Modem Test Call, Test Transfer to Data