Lincoln Electric SVM127-A service manual Troubleshooting & Repair

Models: SVM127-A

1 135
Download 135 pages 50.71 Kb
Page 71
Image 71

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-13

 

F-13

 

TROUBLESHOOTING & REPAIR

 

Observe Safety Guidelines

 

TROUBLESHOOTING GUIDE

 

detailed in the beginning of this manual.

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

The 1/8 amp fuse on the voltage

1. Check to make sure the PC

1. Remove input power to the LN-

 

PC board repeatedly fails.

boards are NOT grounded to

9. Replace the 1/8 amp fuse

 

 

the case of the LN-9. This can

and switch the LN-9 polarity

 

 

happen due to metallic wire

switch to the "NEG" position.

 

 

shavings build-up.

Make a resistance check from

 

 

 

 

 

 

the following leads to the LN-9

 

 

 

case grounding screw: Lead #

 

 

 

500, 510, 525, 522, 526, 530,

 

 

 

and 628.

 

 

 

The resistances should be

 

 

 

above 1000 ohms. If any test

 

 

 

is below 1000 ohms, that circuit

 

 

 

has low resistance to case

 

 

 

ground. Isolate the faulty leads

 

 

 

or PC board. See the Wiring

 

 

 

Diagram and Schematic.

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

LN-9 Wire Feeder

Page 71
Image 71
Lincoln Electric SVM127-A service manual Troubleshooting & Repair