TROUBLESHOOTING & REPAIR

Observe Safety Guidelines

 

 

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

TRIGGER INTERLOCK

 

 

 

FUNCTION PROBLEMS

 

 

 

 

 

The wire feeds when the interlock

1.

Check to see if the reed switch

1. Check the 2CR reed switch for

switch is in the "ON" position. No

 

2CR is stuck closed.

sticking and associated leads

welding or gun trigger activation.

 

 

(#529 and #628) for shorts.

 

 

 

2. The power PC board may be

 

 

 

faulty. Replace.

 

 

 

 

With the interlock switch in the

1.

Check leads #529 and #628 for

1. The 2CR reed switch may be

"ON" position, the wire feed stops

 

loose or faulty connections

faulty. Check to see if it closes

when the gun trigger is released.

 

between the 2CR reed switch

when welding.

 

 

and the power PC board.

2. Check the continuity (zero

 

 

 

 

 

 

ohms) of leads #529 and #628

 

 

 

from the 2CR reed switch to the

 

 

 

power PC board. Also check

 

 

 

continuity of leads #530 and

 

 

 

#522 from the power PC board

 

 

 

to the interlock switch. See the

 

 

 

Wiring Diagram.

 

 

 

3. Check the interlock switch for

 

 

 

proper operation.

 

 

 

4. The power PC board may be

 

 

 

faulty. Replace.

 

 

 

 