F-8

 

F-8

TROUBLESHOOTING & REPAIR

Observe Safety Guidelines

 

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

FUNCTION PROBLEMS

 

The SET speed is adjustable and

1. Contact your local Lincoln

1. While the motor is running,

steady. The actual speed is uncon-

Authorized Field Service

carefully unplug the 15 pin

trollable. The meter displays the

Facility.

molex plug from the control

actual speed correctly or reads

 

board.

"EEE."

 

If the motor continues to run,

 

 

 

 

the power PC board may be

 

 

faulty. Replace.

 

 

If the motor stops, the control

 

 

PC board may be faulty.

 

 

Replace.

 

 

2. Perform the Wire Drive Motor

 

 

Test.

 

 

 

The SET speed is adjustable and

1. Check for loose or faulty con-

1. Check to make sure the slotted

steady. The actual speed reading

nections on leads #510, #525,

disc in the tach housing is

is incorrect, erratic, or zero.

and #555 between the tach

secure and aligned.

 

board and the control PC board.

2. Perform the Tach Board

 

 

 

 

Feedback Test.

 

 

3. If the Tach Board Feedback

 

 

Test is OK, the control PC

 

 

board may be faulty. Replace.

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

LN-9 Wire Feeder