TROUBLESHOOTING & REPAIR

OUT OF VOLTAGE RANGE SHUT DOWN TEST (continued)

Return to

Return to Section TOC

Return to Section TOC

Return to

Return to Master TOC

Return to Master TOC

8.If the ACTUAL voltage reading is zero, the sensing leads may be faulty. Check the con- tinuity (zero ohms) of leads #21 and #67. Lead #21 must have continuity to the work- piece, and #67 must have continuity to the electrode. Also check the 1/8 amp fuse on the voltage PC board.

9.Check the polarity switches in the LN-9 and the Lincoln power source and their associat- ed leads. Set the switches to the same polarity as the electrode. See the Wiring Diagram.

10.If the ACTUAL voltage reading is different from the SET voltage reading, the power source may not be capable of producing the required arc voltage, the control cable may be faulty or misconnected, or the LN-9 volt- age PC board may be faulty.

11.After all tests are complete, remove input power to the wire feeder and remove the jumper you placed on the "BYPASS" pins on the voltage PC board. Reattach the left case side cover assembly.