TROUBLESHOOTING & REPAIR

VOLTMETER ACCURACY TEST (continued)

FIGURE F.8 – VOLTMETER CONNECTION POINT

Return to Section TOC

Return to Master TOC

BRASS

CONDUCTOR

BLOCK

TEST PROCEDURE

Perform the following checks with the LN-9 wire feeder connected to a Lincoln CV welding power source according to the proper connection dia- gram. (See the Installation section of this man- ual.)

See Figure F.8 for this test.

1.Lift the right side cover assembly.

2.Connect the test meter (see Materials Needed) between the brass conductor block on the wire feeder and the work piece.

Return to Section TOC

Return to Master TOC

LN-9 Wire Feeder