TROUBLESHOOTING & REPAIR

 

 

TROUBLESHOOTING GUIDE

 

 

Observe Safety Guidelines

 

detailed in the beginning of this manual.

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

 

 

Circuit breaker (5 amp) repeatedly

1. Check or replace gun trigger

1.

Disconnect lead #500 from the

trips when the gun trigger is acti-

and leads. Make sure the trig-

 

trigger board. If the breaker still

vated.

ger leads are not shorted to the

 

trips when the gun trigger is

 

electrode or work cables.

 

activated, the trigger board may

 

 

 

be faulty. Replace

 

 

 

2.

Disconnect any accessory that

 

 

 

may be connected to terminals

 

 

 

#7 and #32A. See the Wiring

 

 

 

Diagram. If the problem is

 

 

 

resolved, the accessory may be

 

 

 

faulty. Replace.

 

 

 

3.

Perform the Wire Drive Motor

 

 

 

Test.

 

 

 

 

4.

The power PC board may be

 

 

 

faulty. Replace.

 

 

 

 

 

Circuit breaker (5 amp) trips when

1. Disconnect any kits that may be

1.

Disconnect lead #620 from trig-

power is applied to the LN-9. Gun

incorporated in the LN-9 (K202,

 

ger board.

See

the Wiring

trigger is NOT activated.

K319, etc.). Be sure to install

 

Diagram.

If the

problem is

 

any necessary jumper plugs. If

 

resolved, the trigger board may

 

the problem is resolved, the

 

be faulty. Replace.

 

 

fault may be in the disconnect-

2.

Perform the T2 Transformer

 

ed kit.

 

 

Test.

 

 

 

 

 

 

 

 

 

3.

Check the harness leads #32A,

 

 

 

#31, and #531 for shorts or

 

 

 

grounds.

See

the Wiring

 

 

 

Diagram.

 

 

 

 

4.

The power PC board may be

 

 

 

faulty. Replace.

 

 

 

 

 

 

 