TROUBLESHOOTING & REPAIR

METER CIRCUIT ACCURACY TEST (continued)

FIGURE F.10 – METER PC BOARD TEST POINTS

 

TP5

602

 

601 510C

TP4

560

 

561

 

 

517

Return to Section TOC

Return to Master TOC

5.Test for AC supply to the meter PC board.

Check for 8 to 11 VAC from lead #601 to #602. See Figure F.10.

Note: The coating will have to be removed from the test points.

6.Test for DC volts on the meter PC board.

Check for 4.75 to 5.25 VDC from TP5 to lead #510C. See Figure F.10.

NOTE: The coating will have to be removed from the test points.

If the display is NOT lit and the correct DC volt- age is present at TP5 to lead #510C, the digital meter may be faulty. Replace the digital meter.

If AC voltage IS present at leads #601 to #602 and the DC voltage is missing, the meter PC board may be faulty.