TEST PROCEDURE

1.Remove input power to the LN-9 wire feeder.

2.Using the phillips head screw driver, remove the screws from the left side cover assembly.

3.Lift the left side cover assembly.

4.Locate the power PC board and the control PC board in the wire feeder main assembly; locate the voltage PC board in the left side cover.

WARNING

ELECTRIC SHOCK can kill.

With power applied, there are high voltages inside the wire feeder. Do not reach into the wire feeder or touch any internal part of the wire feeder while power is applied.

5.Apply power (115VAC) to the wire feeder at the correct pins. See the Wiring Diagram.

6.Perform the power supply checks as described in the table below. If any of the readings are incorrect (out of range) or miss- ing, the power PC board may be faulty.

NOTE: Do NOT unplug the Molex connector.

7.Also perform the T1 Transformer Test.