Lincoln Electric SVM127-A service manual Terminal

Models: SVM127-A

1 135
Download 135 pages 50.71 Kb
Page 117
Image 117

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

F-59

F-59

TROUBLESHOOTING & REPAIR

T1 TRANSFORMER REMOVAL AND REPLACEMENT (continued)

FIGURE F.20 – TERMINAL STRIP MOUNTING

T1

TERMINAL

STRIP

TRANSFORMER

MOUNTING

 

SCREWS

 

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

11.Using the 5/16" wrench, remove the nuts and lockwashers mounting the terminal strip to the mounting panel. See Figure F.20.

12.Remove the terminal strip and set it aside.

13.Using the 5/16" wrench, remove the two nuts and washers from the T1 transformer mounting screws.

14.Remove the transformer mounting screws and the T1 transformer. This may require gently prying up the control PC board mounting panel. Be sure to clear all leads.

REPLACEMENT

15.Position the T1 transformer and use the 5/16" wrench to attach it with the two nuts and washers.

16.With the 5/16" wrench, mount the terminal strip.

17.Plug the 1CR relay into the power PC board and attach the clip. See Figure F.19.

18.Mount the power PC board mounting panel with the two phillips head screws and 11/32 nut.

19.Connect leads #601 and #602 at the lead splices. See Figure F.18.

20.Connect leads #526 AND #527 at their ter- minals on the power PC board. See Figure

F.17.

21.Solder lead #31 to the R1 (2 ohm) resistor. See Figure F.16.

22.Connect primary lead #532 to its power PC board terminal.

23.Close the left cover and re-attach the screws.

LN-9 Wire Feeder

Page 117
Image 117
Lincoln Electric SVM127-A service manual Terminal