Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-69

F-69

TROUBLESHOOTING & REPAIR

RETEST AFTER REPAIR

Retest the LN-9 wire feeder:

If it fails any test and the test requires removing or replacing any mechanical part that could affect the wire feeder's electrical characteristics.

OR

If you repair or replace any electrical compo- nent.

The wire feeder must meet the following standards under retest:

Wire Feed Speed, LN-9

50 - 600 IPM

Wire Feed Speed, LN-9H

80 - 960 IPM

Voltmeter

Refer to Voltmeter Accuracy Check

Wire Speed Meter

Refer to Meter Circuit Accuracy Test

Gas Solenoid (If Used)

Must function when gun trigger is activated

Voltage control and shutdown

Refer to Out of Voltage Range Shut Down Test

LN-9 Wire Feeder

Page 127
Image 127
Lincoln Electric SVM127-A service manual Retest After Repair, Retest the LN-9 wire feeder