TROUBLESHOOTING & REPAIR

T2 TRANSFORMER TEST (continued)

FIGURE F.4 – T2 PRIMARY LEADS #32A AT 5 AMP CIRCUIT BREAKER AND #531 AT R1 RESISTOR

CIRCUIT

 

BREAKER

LEAD 32A

 

 

LEAD 531

 

 

R1 RESISTOR

4. Locate the T2 transformer primary lead 5.

Lift the left side cover assembly.

#32A connected to the 5 amp circuit break-

6.

Locate T2 transformer primary lead #531

er. Remove lead #32A from the circuit break-

 

connected to the R1 2-ohm resistor. See the

er. See Figure F.4 and the Wiring Diagram.

 

 

Wiring Diagram. See Figure F.4.

 

 

LN-9 Wire Feeder

Page 86
Image 86
Lincoln Electric SVM127-A service manual Circuit Breaker