F-18

 

 

 

 

 

 

F-18

TROUBLESHOOTING & REPAIR

 

TROUBLESHOOTING GUIDE

 

 

 

 

 

Observe Safety Guidelines

 

 

 

 

detailed in the beginning of this manual.

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

METER FUNCTION PROBLEMS

 

 

 

The SET and actual speed meter

1.

Contact your

local

Lincoln

1.

Check to make sure the slotted

readings match within a few IPM,

 

Authorized

Field

Service

 

disc in the tach housing is

but both are in error.

 

Facility.

 

 

 

secure and aligned.

 

 

 

 

 

2.

Perform the

Meter Circuit

 

 

 

 

 

 

Accuracy Test.

 

 

 

 

 

3.

The control board may be faulty.

 

 

 

 

 

 

Replace.

 

 

 

 

 

 

 

 

SET speed and actual speed meter

1.

Contact your

local

Lincoln

1.

Check the Volts - Speed meter

readings do NOT match within a

 

Authorized

Field

Service

 

selector switch and the associ-

few IPM. One or both readings

 

Facility.

 

 

 

ated wiring.

See the Wiring

may be erratic.

 

 

 

 

 

Diagram.

 

 

 

 

 

 

2.

Check the SET - Actual switch

 

 

 

 

 

 

and the associated wiring. See

 

 

 

 

 

 

the Wiring Diagram.

 

 

 

 

 

3.

Perform the

Meter Circuit

 

 

 

 

 

 

Accuracy Test.

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

LN-9 Wire Feeder

Page 76