C-4

ACCESSORIES

C-4

 

 

GUN AND CABLE ASSEMBLIES

 

 

 

 

A variety of standard Lincoln and Magnum gun and

12 ft. and 15 ft. cable lengths.

Choose the gun and

cable assemblies are available for the LN-9 in 10 ft.,

cable assembly to suit the LN-9 welding application

 

 

 

and wire size. See Table C-1.

 

 

TABLE C.1 – LN-9 GUN AND CABLE ASSEMBLIES

 

 

 

 

 

 

 

 

 

 

 

 

60% Duty

Process

Model

 

Electrode

 

Rating

Gas Metal Arc Welding

K497(1)

.025-.045” (0.6-1.14 mm) solid

 

200 amps

 

 

 

 

 

200 amps

 

 

 

 

 

 

K498(2)

.025-.045” (0.6-1.14 mm) solid

 

200 amps

 

 

 

 

 

200 amps

 

 

 

 

 

 

Magnum K470(1)

.035-564 (0.9-2.0 mm) solid

 

300 amps

 

 

 

 

 

300 amps

 

 

 

 

 

 

Magnum K471(1)

.035-564 (0.9-2.0 mm) solid

 

400 amps

 

 

 

 

 

400 amps

 

 

 

 

 

 

Magnum K478(2)

.035-564 (0.9-2.0 mm) solid

 

300 amps

 

 

 

 

 

300 amps

 

 

 

 

 

 

Magnum K479(2)

.035-564 (0.9-2.0 mm) solid

 

400 amps

 

 

 

 

 

400 amps

 

 

 

 

 

Innershield ®

K126

.062-332 (1.6-2.4 mm) Innershield

 

350 amps

 

K115-120

for .120” and 764” (3.0 and 2.8 mm)

 

450 amps

 

K115-3/32

 

for 332” (2.4 mm)

 

450 amps

 

K115-5/64

for .068-564 (1.7-2.0 mm)

 

450 amps

 

K116-120

for 120” and 764” (3.0 and 2.8 mm)

 

600 amps

 

K116-3/32

 

for 332” (2.4 mm)

 

600 amps

 

K206(3)

.062-332 (1.6-2.4 mm) Innershield

 

350 amps

 

K289(3)

.068-.120” (1.7-3.0 mm) lnnershield

 

500 amps

 

K309(3)

.062-332 (1.6-2.4 mm) lnnershield

 

250 amps

Submerged Arc

K112

 

116” (1.6 mm) solid

 

500 amps

 

K113-1

 

564” (2.0 mm)

 

600 amps

 

K113-2

 

332” (2.4 mm)

 

600 amps

 

K-114

332 or 564” (2.4 or 2.0 mm) solid

 

600 amps

 

 

 

 

 

 

(1)K466-1 connector kit required.

(2)K489 Fast-Mate™ Adapter required.

(3)Linconditioner™ guns are recommended for locations where smoke accumulation is a problem and conven- tional exhaust systems are ineffective. The available smoke removal type Innershield guns and vacuum units can be used in these locations. Instructions are shipped with the equipment.