TROUBLESHOOTING & REPAIR

 

 

 

 

TROUBLESHOOTING GUIDE

 

 

 

Observe Safety Guidelines

 

 

 

detailed in the beginning of this manual.

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

 

RECOMMENDED

 

 

 

(SYMPTOMS)

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

STARTING PROBLEMS

 

 

 

 

 

The output voltage is too low to

1. Check the welding cables for

1. Check the

voltage

control

start the weld.

loose or faulty connections.

potentiometer

(R3)

and

the

 

2. Put the Lincoln power source in

associated leads.

See

the

 

Wiring Diagram.

 

 

 

 

the "Machine

Control"

mode.

 

 

 

 

 

 

 

 

 

 

Jumper the "BYPASS" pins on

2. The voltage PC board may be

 

the LN-9 voltage PC board.

faulty. Replace.

 

 

 

 

Adjust the weld voltage from the

 

 

 

 

 

 

power source for the process

 

 

 

 

 

 

being used. If the correct volt-

 

 

 

 

 

 

age cannot be set, the power

 

 

 

 

 

 

source may be faulty.

 

 

 

 

 

 

 

3. Check for correct control cable

 

 

 

 

 

 

connections

to the

power

 

 

 

 

 

 

source.

 

 

 

 

 

 

 

 

4. The control cable may be faulty.

 

 

 

 

 

 

Check or replace.

 

 

 

 

 

 

 

5. The start trimmer on the LN-9

 

 

 

 

 

 

voltage PC board may be set too

 

 

 

 

 

 

low. See Starting Characteris-

 

 

 

 

 

 

tics in the Operation section of

 

 

 

 

 

 

this manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.