TROUBLESHOOTING & REPAIR

 

TROUBLESHOOTING GUIDE

 

Observe Safety Guidelines

 

detailed in the beginning of this manual.

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

FUNCTION PROBLEMS

 

 

The LN-9 shuts down while weld-

1. Make sure the power source

1. Perform Out of Voltage Range

ing. Upon retriggering, the gun the

and wire feeder polarity switch-

Shutdown Test.

unit will weld again for a period of

es are set correctly for the

2. The control cable may be faulty.

time.

process being used.

Check or replace.

 

 

 

2. Make certain the voltage control

3. The voltage PC board may be

 

switch on the Lincoln CV power

 

faulty. Replace.

 

source is set in the "Remote"

 

 

 

 

position.

 

 

 

3. Make sure the #21 lead in the

 

 

 

control cable has continuity to

 

 

 

the work piece.

 

 

 

4. Check the 1/8 amp fuse on the

 

 

 

LN-9 voltage PC board.

 

 

 

Replace if faulty.

 

 

 

5. Be sure the welding power

 

 

 

source is compatible with the

 

 

 

LN-9 and operating properly.

 

 

 

Make sure duty cycle of power

 

 

 

source is not being exceeded.

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

LN-9 Wire Feeder