TROUBLESHOOTING & REPAIR

 

 

TROUBLESHOOTING GUIDE

 

 

 

Observe Safety Guidelines

 

 

 

 

detailed in the beginning of this manual.

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

 

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

STARTING PROBLEMS

 

 

 

The arc voltage appears to rise too

1. Check the welding cables for

1. If a start board is used in the

 

slowly or stubs or blasts at the start

loose or faulty connections.

LN-9, change the jumper to

 

of a weld. Once started the weld-

2. Adjust the "start" trimmer on the

position "A." If the problem is

 

ing is good.

solved, the start board may be

 

voltage PC board. It should be

 

 

faulty. Replace.

 

NOTE: Pulse Power 500 operation

slightly higher than the weld

 

 

 

 

with a filter kit may exhibit these

voltage. See Starting Charac-

2. The voltage PC board may be

 

symptoms.

teristics in the Operation section

faulty. Replace.

 

 

of this manual.

 

 

 

 

 

 

3. Put the Lincoln power source in

 

 

 

 

the "Machine

Control"

mode.

 

 

 

 

Jumper the "BYPASS" pins on

 

 

 

 

the LN-9 voltage PC board.

 

 

 

 

Adjust the weld voltage from the

 

 

 

 

power source for the process

 

 

 

 

being used. If the symptoms

 

 

 

 

persist, the power source may

 

 

 

 

be faulty.

 

 

 

 

 

 

4. Check for correct control cable

 

 

 

 

connections

to the

power

 

 

 

 

source.

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.