WIRE FEEDER ACCESSORIES

BURNBACK DELAY KIT (K202)

Provides a precise control of the electrode burnback at the end of the weld. Prevents crater sticking and provides proper stickout for starting the next weld.

Recommended especially when welding with small (.030-1/16") diameter wire at high wire feed speeds. Also recommended when the semiautomatic gun is mounted in a fixture or on the Squirtmobile in a way that prevents the gun from lifting from the work at the end of the weld.

Install the kit according to the instructions included with the kit.

DUAL PROCESS KIT (K317) - For Wire Feeders

Using Same Polarity

This kit permits the connection of two wire feeders to a single power source. Both feeders must weld with the same electrode polarity. When the trigger of the desired wire feeder is pressed, the power source out- put control leads (#75, #76 and #77) will be connected to that feeder, and the procedure as set on its controls will be provided. The other connected wire feeder will not be feeding wire, but its electrode circuit will be elec- trically hot. The kit mounts at the power source and is connected to the power source terminal strip with the supplied leads. Standard K196 input cable assemblies are used to connect each wire feeder to the dual process control circuit while the electrode lead con- nects to the power source.

Install the kit according to instructions included.

DUAL PROCESS KIT (K318) - With Electrode

Polarity Change Capability

Functions essentially the same as the K317 except that the kit includes two contactors to provide different polarities on the two wire feeders. When connected in this manner and one trigger is pressed, the other elec- trode will be "cold" to ground but "hot" to the other elec- trode. This kit can also be connected to provide the same polarities on each feeder, but the electrode circuit of the one not being used will be cold to work and to the other electrode.

Install the kit according to instructions included.

NOTE: The K317 and K318 Dual Process Kits also include mode change capability, but only when using the DC-600 power source. This feature permits one feeder to weld in CV Innershield mode and the other feeder to weld in CV Submerged Arc mode, as well as both in the same mode.

When using the Pulse Power 500 power source, the K317 or K318 Dual Process Kits can be used only if the procedures are close enough to use the same mode setting. The K317 or K318 cannot switch modes on the Pulse Power 500. An LN-9 may not be used with an LN-7 or LN-8, although two LN-9s may be used togeth- er.

DUAL PROCEDURE KIT (K319)

With the use of this kit, one of two different settings of wire feed speed and voltage can be selected by a tog- gle switch mounted on the gun handle. The kit consists of a control panel which mounts over the standard LN-9 control rheostats. This control panel has four rheostats, a transfer relay and a polarized connector. During installation, the standard security door is mount- ed over the new panel and functions in the same man- ner. All electrical connections are with plugs to speed and simplify the assembly. A 15-foot control cable with a polarized connector on one end for plugging into the new control panel is provided. On the other end of the control cable is a small selector toggle switch and a mounting bracket.

A K302 Extension Control Cable is required when using the K319 with any LN-9F model.

Install the kit according to instructions included.

PULSE POWER FILTER CONVERSION KIT (K442-1)

Required for any LN-9 to be used with a Pulse Power 500 or DC650 Pro power source. Includes a Filter Board and connection harness, easily installed in the control section and plugged into the Voltage Board. The plug must be disconnected for use with other stan- dard power sources.

Install the kit according to instructions included.