TROUBLESHOOTING GUIDE

 

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

 

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

 

 

 

 

No wire feed when gun trigger is

1. The Ground Lead Protector

1.

The 1CR relay on the power PC

 

activated. The drive rolls do not

may have tripped. Reset and

 

board may be faulty. Check or

 

turn. The digital meter does light

clear possible fault between

 

replace.

 

 

 

 

but reads only the SET voltage and

electrode circuit and feeder

2.

Check resistor R1.

Normal

 

wire speed values.

frame.

 

 

resistance is 2 ohms. See the

 

 

 

 

 

 

2. The gun trigger may be faulty.

 

Wiring Diagram.

 

 

 

 

 

3.

Perform

the

Trigger

 

 

 

 

Transformer T2 Test.

 

 

 

 

 

3.

Perform

the Trigger

Board

 

 

 

 

Test.

 

 

 

 

 

 

4.

Perform the Wire Drive Motor

 

 

 

 

Test.

 

 

 

 

 

 

5.

If the wire drive motor is OK,

 

 

 

 

then the power PC board or the

 

 

 

 

control PC board may be faulty.

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.