APPENDIX F: Administration Error Messages

 

ERROR MESSAGE

 

 

AND DESCRIPTlON

POSSIBLE SOLUTION

 

 

 

 

1017:

inappropriate

request

Cap already installed

 

system already has Direct

ACTION = 1 (Cap)

 

C A P

 

 

 

Go to MENU 8 (Searches)

 

 

 

 

 

 

ACTION = 1 DATA = 18

 

 

 

ACTION = 2 DATA = 309 or 310

 

 

 

ACTION = 3 DATA = 0

1 0 1 8 :

inappropriate

request

Must remove secondary CAP before

 

must remove

secondary

attempting to remove the first CAP.

 

CAP first

 

 

1 0 1 9 :

incorrect action number

Check if the ACTION value taken is

 

does not exist or used

legal.

 

improperly

 

 

1 0 2 0 : inappropriate request

Trying to administer features to a

 

primary or secondary

secondary CAP that does not exist.

 

CAP does not exist

 

1021:

at installed max

At the maximum number of stations

 

-200 stations

 

allowed by the system.

1022:

at installed max

At the maximum number of trunks

 

-104 trunk

 

allowed by the system.

1023:

button function code

Button station out of range for

 

out of range

 

terminal type code. Check station

 

does not exist or used

for button range. (invalid button

 

improperly

 

function code)

1024:

at installed max

At system maximum of 300 FPDCs.

 

-300 FPDCs

 

 

1025:

at installed max -199

At system maximum of 199 EMT

 

EMT sets

 

s e t s .

1026:

at installation max

Maximum of 111 ATL sets, 2 of

 

-96 ATL set

 

which have to be CAPS

1027:

at installed max

At system maximum of 104

 

-104 trunk

 

ground-start trunks.

1028:

at installed max

At system maximum of 104 loop-

 

-104 trunk

 

start trunks.

1029:

at installed max

At system maximum of 104 DID

 

-104 trunk

 

t r u n k s .

1030:

at installed max

At system maximum of 32 TIE

 

-32 Tie trunk

 

trunks.

F-3

Page 381
Image 381