Figure C-3. DS1 Network Interface Connections

Replace Voice-Only Terminal With Voice/Data Terminal

1.Using the Voice and Data Station Records Form (see “INSTALL EQUIPMENT ROOM STATION CABLING” in section 2), find the jack in the SIP adapter associated with the voice terminal that is to share a cable with. a data terminal or personal computer.

2.Remove the plug (leg of the octopus cable) from the modular jack of the SIP adapter.

3.Insert a Y plug adapter in the same modular jack of the SIP (see “Make SIP Connections for Data Terminals and Computers” in section 2).

4.Insert the modular plug on the octopus cable into the voice side of the Y adapter.

5.Select an unused modular plug that is attached to a TN726 Data Line CP (or, add a TN726 CP and its octopus cable if there are none).

6.Insert the plug into the data side of the Y adapter.

7.Document the change.

8.Install the appropriate ADU, following the procedures under “Install Terminals” in Section 2.