MAINTENANCE

ERROR MESSAGE

 

POSSIBLE SOLUTION

AND DESCRIPTION

 

 

 

 

 

DXS Reset; The DXS console has

Recoverable; no action required.

been reset.

 

 

 

 

 

Electronic

P o w er

F e e d

O f f ,

Check the wiring for shorts from

Overcurrent:

A Hybrid

Line

the backplane/SIP up to the

(ZTN79) port EPF chip shut down.

phone jack. Check the ATL set at

Two ports are effected, for

the SIP. Try swapping ATL sets.

example, 1-2,3-4,5-6,7-8.

 

Error removed if Audit passed and

 

 

 

 

 

short removed. Audit runs every 4

 

 

 

 

 

minutes.

 

 

 

Electronic

Power Feed Overload:

Check the tie trunk pairs from the

A Tie Trunk (TN760B) port EPL

back of the cabinet through to the

chip went into overload.

 

network for an external short (see

 

 

 

 

 

Figure 4-4).If the short is not

 

 

 

 

 

detected on the pairs, replace the

 

 

 

 

 

board .

 

 

 

 

 

Electronic

Power

Feed

Test

Check the E and M leads for

Overload: The “M” lead on a tie

external shorts (see Figure 4-4).If

trunk has an external short circuit.

the short is not on the pairs,

 

 

 

 

 

replace the board.

 

 

Empty CSMA Queue: (STAR LAN

If the reset is not successful

Interface CP) This error resets the

reseat board. If the reseat fails,

C P .

 

 

 

 

replace the CP.

 

 

Error Log Table Full: Transient

Correct indicated errors, and then

Error Log is full.

 

 

 

remove entries from the Transient

 

 

 

 

 

Error Log to free-up space.

 

 

External RAM Failure: Port or

Reseat board. If problem persists,

CPU/Memory

CP

error while

check or replace appropriate CP.

r u n n i n g

background

non-

 

destructive external RAM tests.

 

 

 

 

 

 

 

4-36

Page 212