MAINTENANCE

Error records in the Most Recent System Errors table have a slightly different format. A typical error record from the Most Recent System Errors table is

 

MOST RECENT SYSTEM ERRORS

P O R T BOARD

DATE

TIME

NAME

NUMBER CODE

OCCURRED OCCURRED

 

30300

ZTN131

03/12/85

2:01:56

Port Board Missing

 

 

 

 

But Administered

Interpret this record as follows:

“Port Number” 30300 is the 5-digit port identification number.

“Board Code” ZTN131 is the circuit pack on which the error occurred (or that is associated with the error if this is an off-board error).

“Date Occurred” 03/1 2/85 is the date this error occurred. A conventional calendar designation is used.

“Time Occurred” 12:01:56 is the time this error occurred. A 24-hour clock is used.

“Name” Port Board Missing But Administered is a description of the nature of the error.

A combined total of 40” (R1V1 ) or 50” (RIV2, R2V1, R3) error records for Permanent System Alarms and Transient System Errors is stored by the system. Ten error records are stored in the Most Recent System Errors table. Errors are displayed in the order that they occurred.

Two or more instances of the same error result in only two entries in the log (that is, the first and last occurrence).

4-29

Page 205
Image 205
ADTRAN 25 manual Most Recent System Errors, R T Board Date Time Name Number Code Occurred Occurred