INSTALLATION
Table
Circuit Pack Type | LEDs if Normal | LEDs if Failed | |
Service Circuit (ZTN85 | Steady Green and | Steady Red or | |
or ZTN131 [R3]) | Flashing or | Amber | Off |
| Steady Amber |
|
|
|
|
|
|
CPU/Memory (ZTN129 | Flashing Green | Steady | Green |
or ZTN130 [R3]) |
| or Off |
|
|
|
|
|
All Other | Steady Green | Steady | Red |
| (Amber Also lighted | (see Note below) | |
| when CP in use) |
|
|
|
|
|
|
Note: The red and green LEDs can both be lighted at the same time. In normal operation, a lighted red LED indicates that an alarm has been recorded for that CP. If the green LED is also lighted, the main processor can communicate with the CP. A lighted amber LED indicates that a resource on the CP is being used. A lighted red LED and a dark green LED indicates that the CP diagnosed itself to be so bad that it has removed itself from the system.