MAINTENANCE
Overheating Trouble
A clogged or dirty air filter can cause the cabinet to overheat. The cabinet air filter rests on the floor of the cabinet under the CP carrier. The air filter should be inspected on any service call and replaced as needed (with air filter comcode 845948348).
Caution: Check underneath cabinet for paper and other debris that could clog the air filter and cause the cabinet to overheat .
To replace the air filter, pinch it in the center and pull straight out.
Warning: To reduce risk of fire, air filter must be in place during o p e r a t i o n .
Backplane and Cabinet Trouble
The backplane provides power, TDM bus connections, and station and trunk interconnections. Each carrier has 12 universal slot positions. Any port CP can be installed in any slot. Connection to the corresponding stations or trunks is made through the backplane to the appropriate
Danger: Hazardous voltages are present on some backplane
pins. Unplug the power cord and wait at least 5 minutes
before removing the rear cover.